Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Determination of Cotinine in Urine and Saliva Using Hydrophilic Interaction Liquid Chromatography and Tandem Mass Spectrometry
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för analytisk kemi.
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för analytisk kemi.
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för analytisk kemi.
2011 (engelsk)Inngår i: Analytical Chemistry Letters, ISSN 2229-7928, Vol. 1, nr 1, s. 25-33Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A new simplified method for monitoring of cotinine in urine and saliva, based on hydrophilic interaction liquid chromatography (HILIC) and tandem mass spectrometry (MS) is presented. Work-up techniques based on filtration, using 0.45 μm pore sizepolypropylene filter, of crude urine and saliva and alkaline extraction of cotinine with methylene dichloride were studied. Multiple reaction monitoring (MRM) of the protonated molecular ions of cotinine and tri-deuterium labelled cotinine resulted in selective determinations with linear calibration graphs (correlation coefficients >0.999) The precision for 10 samples, containing 100 ng cotinine /ml, prepared from urine and saliva by methylene dichloride extraction or filtration were between 2 and 5 %. The detection limit for extracted and filtrated saliva was 2 fmol and for extracted and filtrated urine it was 5 and 9 fmol, respectively. Agreement was obtained for the two different work-up techniques. Extraction of urine/saliva enabled detection at lower levels (down to 5 pg cotinine/ml of urine) compared to filtration, since the possibility of enrichment of the sample but also due to reduction of interfering compounds present in the matrix. However, when performing large exposure studies with many samples to be analysed, the simplified and time saving work-up procedure obtained with filtration is valuable.

The higher organic content of the effluent in the HILIC mode and a more efficient separation of polar compounds present in the matrix, favoured the electrospray ionisation compared to reversed phase (RP) LC, thus enabling lower detection limits.

sted, utgiver, år, opplag, sider
2011. Vol. 1, nr 1, s. 25-33
Emneord [en]
Cotinine, hydrophilic interaction liquid chromathography, mass spectrometry
HSV kategori
Identifikatorer
URN: urn:nbn:se:su:diva-84000DOI: 10.1080/22297928.2011.10648202OAI: oai:DiVA.org:su-84000DiVA, id: diva2:578003
Tilgjengelig fra: 2012-12-17 Laget: 2012-12-17 Sist oppdatert: 2013-08-19bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Karlsson, DanielSkarping, GunnarDalene, Marianne
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 21 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf