Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Estimating Image Quality for Future Generations of TOF PET Scanners
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum.
2013 (engelsk)Inngår i: IEEE Transactions on Nuclear Science, ISSN 0018-9499, E-ISSN 1558-1578, Vol. 60, nr 1, s. 87-94Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Images taken with time-of-flight (TOF) positron emission tomography (PET) scanners are of improved quality compared to equivalent non-TOF images. This improvement is dependent on the scanner time resolution. The present generation of commercial TOF scanners has a time resolution in the range of 500-600 ps full width half maximum. In this work we investigate how the image characteristics will improve for future generations of TOF PET. We performed a Geant4 simulation of a 30-cm uniform cylinder containing hot spheres, with time resolution ranging from 600 to 200 ps. Data were reconstructed using TOF filtered back projection (FBP) and TOF ordered subsets expectation maximization (OSEM), with nonTOF reconstruction as a reference. Images were compared in terms of contrast recovery and variance in the image. The TOF gain was evaluated for both reconstruction methods. The TOF gain was also evaluated vs. counts in the scan, in order to understand the behavior of such gain at very low statistics. Using TOF FBP, it was shown that the TOF gain can be used as a sensitivity amplifier, reducing (according to the expected TOF gain) the number of counts necessary to produce an image of the same characteristics. Some limitations in the TOF gain were observed at very low counts, particularly if using iterative methods.

sted, utgiver, år, opplag, sider
2013. Vol. 60, nr 1, s. 87-94
Emneord [en]
Filtered back projection (FBP), low statistics imaging, signal-to-noise ratio (SNR), time-of-flight (TOF) gain, TOF positron emission tomography (PET), time resolution
HSV kategori
Identifikatorer
URN: urn:nbn:se:su:diva-88676DOI: 10.1109/TNS.2012.2233214ISI: 000314972900012OAI: oai:DiVA.org:su-88676DiVA, id: diva2:613031
Merknad

AuthorCount:3;

Tilgjengelig fra: 2013-03-26 Laget: 2013-03-25 Sist oppdatert: 2017-12-06bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Eriksson, Lars
Av organisasjonen
I samme tidsskrift
IEEE Transactions on Nuclear Science

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 58 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf