Physics of pure and non-pure positron emitters for PET: a review and a discussion
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum. Karolinska Institute, Sweden; Siemens Healthcare Molecular Imaging, USA; University of Tennessee, USA.
Rekke forfattare: 22016 (engelsk)Inngår i: EJNMMI Physics, ISSN 2197-7364, Vol. 3, nr 1, artikkel-id 8Artikkel, forskningsoversikt (Fagfellevurdert) Published
Abstract [en]

With the increased interest in new PET tracers, gene-targeted therapy, immunoPET, and theranostics, other radioisotopes will be increasingly used in clinical PET scanners, in addition to F-18. Some of the most interesting radioisotopes with prospective use in the new fields are not pure short-range beta(+) emitters but can be associated with gamma emissions in coincidence with the annihilation radiation (prompt gamma), gamma-gamma cascades, intense Bremsstrahlung radiation, high-energy positrons that may escape out of the patient skin, and high-energy gamma rays that result in some e(+)/e(-) pair production. The high level of sophistication in data correction and excellent quantitative accuracy that has been reached for F-18 in recent years can be questioned by these effects. In this work, we review the physics and the scientific literature and evaluate the effect of these additional phenomena on the PET data for each of a series of radioisotopes: C-11, N-13, O-15, F-18, Cu-64, Ga-68, Br-76, Rb-82, Y-86, Zr-89, Y-90, and I-124. In particular, we discuss the present complications arising from the prompt gammas, and we review the scientific literature on prompt gamma correction. For some of the radioisotopes considered in this work, prompt gamma correction is definitely needed to assure acceptable image quality, and several approaches have been proposed in recent years. Bremsstrahlung photons and Lu-176 background were also evaluated.

sted, utgiver, år, opplag, sider
2016. Vol. 3, nr 1, artikkel-id 8
Emneord [en]
PET, Radioisotopes, Positron emitter, Prompt gamma, Non-conventional PET isotopes
HSV kategori
Identifikatorer
URN: urn:nbn:se:su:diva-132506DOI: 10.1186/s40658-016-0144-5ISI: 000379211600001PubMedID: 27271304OAI: oai:DiVA.org:su-132506DiVA, id: diva2:952960
Tilgjengelig fra: 2016-08-16 Laget: 2016-08-15 Sist oppdatert: 2016-08-16bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Eriksson, Lars
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 69 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf