Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Patterns of practice of image guided particle therapy for cranio-spinal irradiation: A site specific multi-institutional survey of European Particle Therapy Network
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 123, artikel-id 103407Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: To investigate the current practice patterns in image-guided particle therapy (IGPT) for cranio-spinal irradiation (CSI).

Methods: A multi-institutional survey was distributed to European particle therapy centres to analyse all aspects of IGPT. Based on the survey results, a Delphi consensus analysis was developed to define minimum requirements and optimal workflow for clinical practice. The centres participating in the institutional survey were invited to join the Delphi process.

Results: Eleven centres participated in the survey. Imaging for treatment planning was rather similar among the centres with Computed Tomography (CT) being the main modality. For positioning verification, 2D IGPT was more commonly used than 3D IGPT. Two centres performed routinely imaging for plan adaptation, by the rest ad hoc. Eight centres participated in the Delphi consensus analysis. The full consensus was reached on the use of CT imaging without contrast for treatment planning and the role of magnetic resonance imaging (MRI) in target and organs-at-risk delineation. There was an agreement on the necessity to perform patient position verification and correction before each isocentre. The most important outcome was the clear need for standardization and harmonization of the workflow.

Conclusion: There were differences in CSI IGPT clinical practice among the European particle therapy centres. Moreover, the optimal workflow as identified by experts was not yet reached. There is a strong need for consensus guidelines. The state-of-the-art imaging technology and protocols need to be implemented into clinical practice to improve the quality of IGPT for CSI.

Ort, förlag, år, upplaga, sidor
2024. Vol. 123, artikel-id 103407
Nyckelord [en]
Cranio-spinal axis, Proton therapy, Image guided proton therapy
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:su:diva-232500DOI: 10.1016/j.ejmp.2024.103407ISI: 001259361900001PubMedID: 38906046Scopus ID: 2-s2.0-85196270777OAI: oai:DiVA.org:su-232500DiVA, id: diva2:1890020
Tillgänglig från: 2024-08-18 Skapad: 2024-08-18 Senast uppdaterad: 2024-09-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Toma-Daşu, Iuliana

Sök vidare i DiVA

Av författaren/redaktören
Toma-Daşu, Iuliana
Av organisationen
Fysikum
I samma tidskrift
Physica medica (Testo stampato)
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 20 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf