Current and Future Use of LSO:Ce Scintillators in PET
University Tennessee. (Scintillation Materials Research)
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum. (Siemens Molecular Imaging)
(Siemens Molecular Imaging)
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum. (Siemens Molecular Imaging)
Vise andre og tillknytning
2006 (engelsk)Inngår i: Radiation detectors for medical applications / [ed] Stefaan Tavernier, Dordrecht: Springer , 2006, , s. 243-257s. 243-257Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Single crystal scintillators of Lu2SiO5:Ce (LSO:Ce) were first developed about 15 years ago and have been in commercial use in positron emission tomography systems for more than five years. Annual production now exceeds 10,000 kg. We review the development of LSO:Ce and its implementation in PET, and summarize the current understanding of the scintillation characteristics and mechanisms. In addition, we present the evolution of LSO:Ce detector design and consider the potential performance of future imaging systems. In particular, coincidence timing measurements are presented and time-of-flight systems that take better advantage of the timing characteristics of LSO:Ce are discussed.

sted, utgiver, år, opplag, sider
Dordrecht: Springer , 2006. , s. 243-257s. 243-257
Serie
NATO security through science series. Series B, Physics and biophysics
Identifikatorer
URN: urn:nbn:se:su:diva-31785ISBN: 978-1-4020-5091-6 (tryckt)OAI: oai:DiVA.org:su-31785DiVA, id: diva2:278547
Konferanse
NATO Advanced Research Workshop on Radiation Detectors for Medical Applications
Tilgjengelig fra: 2009-11-26 Laget: 2009-11-26 Sist oppdatert: 2009-12-22bibliografisk kontrollert
Inngår i avhandling
1. Detector Considerations for Time-of-Flight in Positron Emission Tomography
Åpne denne publikasjonen i ny fane eller vindu >>Detector Considerations for Time-of-Flight in Positron Emission Tomography
2009 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Positron-Emission-Tomography (PET) is a modern imaging technique in nuclear medicine providing quantitative 3D distribution of a radioactive tracer substance in the human body. The gamma-detector is the first link in the chain of components that constitutes a PET. It converts incoming radiation into optical light pulses, which are detected by photo multiplier tubes. Here the light is converted into electric pulses, to be further processed by the acquisition electronics. Improving detector sensitivity and resolution is of great value in research and in clinical practice.

The focus of this work is to improve the detector to give it time-of-flight (TOF) capabilities, in order to further improve sensitivity, which in turn leads to increased image quality, faster scan time and/or reduced dose exposure for the patient.

Image quality has improved over the years, but losses in image quality have been reported for heavy patients, due to increased attenuation, and more dispersed counts over a larger volume. Instrumentation limits are still significant in heavy patient images, but the incorporation of TOF information promises to alleviate some of the limitations.

In order to improve the timing resolution of the detector fast photo-multipliers and a novel scheme to extract the event timing trigger from a detector by using the summed dynode signal were investigated.

When designing new PET detectors, it is important to have detailed understanding and control of the light sharing mechanisms in the crystal arrays. Therefore it was necessary to perform optical simulations and single crystal light output measurements to derive a model for an LSO block detector.

Another way to improve the image quality is to use the depth-of-interaction (DOI) of the gamma ray within the detector. It is shown that a multi-layer phoswich detector comprised of LSO with different decay times and TOF capability, combines the benefits of TOF and DOI in one detector, maximizing the effective sensitivity gain.

sted, utgiver, år, opplag, sider
Stockholm: Department of Physics, Stockholm University, 2009. s. 78
Emneord
Positron Emission Tomography, Time of Flight, Depth of Interaction, LSO
HSV kategori
Forskningsprogram
medicinsk strålningsfysik
Identifikatorer
urn:nbn:se:su:diva-31587 (URN)978-91-7155-979-1 (ISBN)
Disputas
2010-01-08, FB52, AlbaNova universitetscentrum, Roslagstullsbacken 21, Stockholm, 10:00 (engelsk)
Opponent
Veileder
Merknad
At the time of the doctoral defense, the following papers were unpublished and had a status as follows: Paper 7: Submitted. Tilgjengelig fra: 2009-12-03 Laget: 2009-11-19 Sist oppdatert: 2009-12-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Link to doctoral thesis

Søk i DiVA

Av forfatter/redaktør
Eriksson, L.Bauer, F.
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 109 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf