Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Analysis of Bias in the Apparent Correlation Coefficient Between Image Pairs Corrupted by Severe Noise
Stockholms universitet, Naturvetenskapliga fakulteten, Wenner-Grens institut.
Stockholms universitet, Naturvetenskapliga fakulteten, Wenner-Grens institut.
2010 (Engelska)Ingår i: Journal of Mathematical Imaging and Vision, ISSN 0924-9907, E-ISSN 1573-7683, Vol. 37, nr 3, s. 204-219Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The correlation coefficient r is a measure of similarity used to compare regions of interest in image pairs. In fluorescence microscopy there is a basic tradeoff between the degree of image noise and the frequency with which images can be acquired and therefore the ability to follow dynamic events. The correlation coefficient r is commonly used in fluorescence microscopy for colocalization measurements, when the relative distributions of two fluorophores are of interest. Unfortunately, r is known to be biased understating the true correlation when noise is present. A better measure of correlation is needed. This article analyses the expected value of r and comes up with a procedure for evaluating the bias of r, expected value formulas. A Taylor series of so-called invariant factors is analyzed in detail. These formulas indicate ways to correct r and thereby obtain a corrected value free from the influence of noise that is on average accurate (unbiased). One possible correction is the attenuated corrected correlation coefficient R, introduced heuristically by Spearman (in Am. J. Psychol. 15:72-101, 1904). An ideal correction formula in terms of expected values is derived. For large samples R tends towards the ideal correction formula and the true noise-free correlation. Correlation measurements using simulation based on the types of noise found in fluorescence microscopy images illustrate both the power of the method and the variance of R. We conclude that the correction formula is valid and is particularly useful for making correct analyses from very noisy datasets.

Ort, förlag, år, upplaga, sidor
2010. Vol. 37, nr 3, s. 204-219
Nyckelord [en]
Correction correlation coefficient, Severely degraded images
Nationell ämneskategori
Cellbiologi
Identifikatorer
URN: urn:nbn:se:su:diva-49910DOI: 10.1007/s10851-010-0200-zISI: 000278580600002OAI: oai:DiVA.org:su-49910DiVA, id: diva2:380346
Anmärkning
authorCount :3Tillgänglig från: 2010-12-21 Skapad: 2010-12-20 Senast uppdaterad: 2022-02-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Parmryd, Ingela

Sök vidare i DiVA

Av författaren/redaktören
Parmryd, Ingela
Av organisationen
Wenner-Grens institut
I samma tidskrift
Journal of Mathematical Imaging and Vision
Cellbiologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 202 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf