Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A new modified Edman procedure for analysis of N-terminal valine adducts in hemoglobin by LC-MS/MS
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för material- och miljökemi (MMK).
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för material- och miljökemi (MMK).
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för material- och miljökemi (MMK).
2010 (Engelska)Ingår i: Journal of chromatography. B, ISSN 1570-0232, E-ISSN 1873-376X, Vol. 878, nr 27, s. 2483-2490Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A rapid and sensitive method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for simultaneous determination of adducts from acrylamide, glycidamide and ethylene oxide to N-terminal valines in hemoglobin (Hb) was developed. This new procedure is based on the same principles as the N-alkyl Edman procedure for analysis of adducts from electrophilic agents to N-terminal valines in Hb. The N-substituted valines can be detached, enriched and measured selectively as thiohydantoins by the use of an Edman reagent, in this case fluorescein isothiocyanate (FITC). This procedure is denoted as the "adduct FIRE procedure" as the FITC reagent is used for measurement of adducts ((R) under bar) formed from electrophilic compounds with a modified Edman procedure. In this study, fluorescein thiohydantoin (FTH) analytes of N-substituted valines from acrylamicle, glycidamide and ethylene oxide, as well as their corresponding hepta- and tri-deuterium-substituted analogues, were synthesized. These analytes (n = 8) were then characterized by LC-MS/MS (ESI, positive ion mode) and obtained product ions were interpreted. A considerable work with optimization of the FIRE procedure (TM), resulted in a procedure in which low background levels of the studied adducts could be measured from 250 mu L lyzed whole blood samples (human non-smokers). The analytes were enriched and purified with solid phase extraction columns and analyzed by LC-MS/MS with LOQ clown to 1 pmol adduct/g Hb. Compared to other procedures for determination of N-terminal Hb adducts, the introduction of FITC has led to a simplified procedure, where whole blood also can be used, giving new opportunities and reduced hand on time with increased sample throughput.

Ort, förlag, år, upplaga, sidor
2010. Vol. 878, nr 27, s. 2483-2490
Nyckelord [en]
Hemoglobin adducts, Acrylamide, Ethylene oxide, Modified Edman, Adduct FIRE procedure, LC-MS/MS
Nationell ämneskategori
Kemi
Forskningsämne
miljökemi
Identifikatorer
URN: urn:nbn:se:su:diva-51442DOI: 10.1016/j.jchromb.2010.03.034ISI: 000283410200004OAI: oai:DiVA.org:su-51442DiVA, id: diva2:385679
Anmärkning
authorCount :3Tillgänglig från: 2011-01-12 Skapad: 2011-01-10 Senast uppdaterad: 2017-12-11Bibliografiskt granskad
Ingår i avhandling
1. Methodology for hemoglobin adduct measurement: Fetal exposures to acrylamide and other genotoxic agents
Öppna denna publikation i ny flik eller fönster >>Methodology for hemoglobin adduct measurement: Fetal exposures to acrylamide and other genotoxic agents
2011 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

There is increasing evidence that exposure to toxic chemicals during the prenatal period constitute a higher health risk than exposure during adulthood. To characterize exposure and identify risk factors, sensitive methods for analysis of chemicals in vivo with biomarker methods are needed. Adducts to hemoglobin (Hb) have been shown useful as biomarkers of dose in blood of reactive compounds/metabolites, which are toxic due to reactions with biomacromolecules.

The aim of this thesis was to develop a new method for the analysis of Hb adducts suitable for analysis of large sample series, and then to apply the method for measurements of Hb adducts from exposure to acrylamide, glycidamide and ethylene oxide in mother/cord blood samples from five European countries.

A new method for measurements of N-terminal Hb adducts, denoted the adduct FIRE procedure, was developed using the fluorescein isothiocyanate Edman reagent. With the new procedure, optimized for LC/MS analysis, a high sensitivity and reproducibility was achieved. The new method made it possible to perform measurements of low exposures to the studied genotoxic compounds in approximately 1350 maternal and cord blood samples.

The results show that the fetus is exposed to a similar in vivo dose of the studied compounds as the mother. The measured Hb adduct levels show that acrylamide exposure from food intake is higher for the participating mothers fromUK compared to the mothers from the other countries. The measured Hb adduct levels form a basis for evaluations of relationships between exposure and health risks, and ongoing studies indicate associations between acrylamide Hb adduct levels and birth weight.

The developed method was also used for identification of an unknown Hb adduct, which was shown to originate from methyl vinyl ketone (MVK), a highly reactive and toxic compound. The identity of the adduct was confirmed with synthesized standards. There exist both natural and anthropogenic sources to MVK, and to what extent the MVK-adduct reflects exogenous exposure is yet not clarified.

Ort, förlag, år, upplaga, sidor
Stockholm: Department of Materials and Environmental Chemistry (MMK), Stockholm University, 2011. s. 54
Nationell ämneskategori
Kemi
Forskningsämne
miljökemi
Identifikatorer
urn:nbn:se:su:diva-63026 (URN)978-91-7447-376-6 (ISBN)
Disputation
2011-11-11, Magnélisalen, Kemiska övningslaboratoriet, Svante Arrhenius väg 16 B, Stockholm, 10:00 (Svenska)
Opponent
Handledare
Anmärkning
At the time of the doctoral defense, the following paper was unpublished and had a status as follows: Paper 3: Epub ahead of print.Tillgänglig från: 2011-10-20 Skapad: 2011-10-07 Senast uppdaterad: 2011-10-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
von Stedingk, HansRydberg, PerTörnqvist, Margareta
Av organisationen
Institutionen för material- och miljökemi (MMK)
I samma tidskrift
Journal of chromatography. B
Kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 383 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf