Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Towards Sub-Minute PET Examination Times
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum.
Vise andre og tillknytning
2011 (engelsk)Inngår i: IEEE Transactions on Nuclear Science, ISSN 0018-9499, E-ISSN 1558-1578, Vol. 58, nr 1, s. 76-81Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The main performance parameters in positron camera system design are sensitivity and spatial resolution. This paper concerns sensitivity, which is a function of the scintillation material, the solid angle subtended by the detector array, and the scintillator packing fraction. The solid angle can be increased by extending the axial extent of cylindrical detector systems. Most commercial positron camera systems are based on rings of detector blocks with lutetium oxyorthosilicate, LSO:Ce or LYSO:Ce, as the scintillator of choice. By adding more rings, the solid angle and thus the absolute sensitivity increases while the singles detection efficiency remains fairly constant assuming the same crystal thickness. It has been shown that Ca co-doping of LSO:Ce reduces the scintillation decay time to similar to 30 ns with a light output over 30000 ph/MeV. This improvement may give a time-of-flight (TOF) advantage with time resolution of 500 ps or less. If the count rate sensitivity of a large axial field-of-view (AFOV) system is combined with the TOF sensitivity increase, we have the means to create examination times in the sub-minute range with no compromise in image quality. In the present study we have compared the existing Siemens molecular CT (mCT) systems to future 6, 8, 12, 20 and higher block ring systems with and without TOF. The mCT 4 block ring system has been used as a reference. The time for acceptable image quality with this system is then extrapolated to other systems based on planar sensitivity. However, the planar sensitivity is related to the solid angle, and reaches saturation for large AFOVs. This implies that there is an upper count rate sensitivity limit. A 20 block ring system may cover a 70 cm examination range at a certain planar count rate and could provide acceptable quality images in approximately 10 seconds by combining the high planar sensitivity count rate provided by the multi-ring feature, the high stopping power of LSO and the TOF gain due to the improved timing resolution. The increased sensitivity may be used to reduce patient dose.

sted, utgiver, år, opplag, sider
2011. Vol. 58, nr 1, s. 76-81
Emneord [en]
Molecular imaging, positron emission tomography (PET), time-of-flight imaging (TOF)
HSV kategori
Identifikatorer
URN: urn:nbn:se:su:diva-67509DOI: 10.1109/TNS.2010.2096542ISI: 000287086900010OAI: oai:DiVA.org:su-67509DiVA, id: diva2:470442
Merknad
authorCount :8Tilgjengelig fra: 2011-12-29 Laget: 2011-12-28 Sist oppdatert: 2017-12-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Eriksson, Lars
Av organisasjonen
I samme tidsskrift
IEEE Transactions on Nuclear Science

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 60 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf