Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
micMicroextraction by packed sorbent and liquid chromatography-tandem mass spectrometry as a tool for quantification of peptides in plasma samples: determination of sensory neuron-specific receptors agonist BAM8-22 and antagonist BAM22-8 in plasma samples
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för analytisk kemi.
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för analytisk kemi.
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för analytisk kemi.ORCID-id: 0000-0002-3862-8878
2013 (Engelska)Ingår i: BMC Biomedical chromotography, ISSN 0269-3879, E-ISSN 1099-0801, Vol. 27, nr 3, s. 396-403Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Microextraction by packed sorbent (MEPS) is a miniaturized, solid-phase extraction (SPE) technique that works online with gas chromatography (GC) and liquid chromatography (LC). Not only is the automation process with MEPS advantageous, but the much smaller volumes of the samples, solvents and dead space in the system also provide other significant advantages such as the speed and the simplicity of the sample preparation process. In this study MEPS has been evaluated for quantification of sensory neuron-specific receptors agonist (BAM8-22). Owing to the instability of BAMs, the focus was on fast extraction and determination of the peptide online using LC-MS/MS. Sorbents such as C2, C8 and ENV+ (hydroxylated polystyrenedivinylbenzene copolymer) were investigated in the present study. MEPS-C8 gave the best results compared with C2 and ENV and it was used for the method validation. The calibration curve was obtained within the concentration range of 20.03045nmol/L in plasma. The regression correlation coefficients for plasma samples were 0.99 for all runs (n=6). The between-batch accuracy and precision for BAM8-22 ranged from 13 to 2.0% and from 4.0 to 14%, respectively. Additionally, the accuracy and precision for BAM22-8 ranged from 13 to 7.0% and from 3.0 to 12%, respectively. The present method was used for pharmacokinetic studies for BAMs in plasma samples.

Ort, förlag, år, upplaga, sidor
2013. Vol. 27, nr 3, s. 396-403
Nyckelord [en]
BAM peptides, plasma samples, microextraction by packed sorbent, liquid chromatography, mass spectrometry
Nationell ämneskategori
Biokemi och molekylärbiologi
Identifikatorer
URN: urn:nbn:se:su:diva-88289DOI: 10.1002/bmc.2806ISI: 000314471700019OAI: oai:DiVA.org:su-88289DiVA, id: diva2:610699
Anmärkning

AuthorCount:3;

Tillgänglig från: 2013-03-12 Skapad: 2013-03-12 Senast uppdaterad: 2019-12-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Daryanavard, MosayebAbdel-Rehim, Mohamed
Av organisationen
Institutionen för analytisk kemi
I samma tidskrift
BMC Biomedical chromotography
Biokemi och molekylärbiologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 335 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf