Development and validation of a scanned proton beam model for dose distribution verification using Monte Carlo
Stockholm University, Faculty of Science, Department of Physics.
2015 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Background and purpose: Although proton therapy is becoming increasingly common as a radiotherapy modality, facilities offering proton therapy are still scarce in comparison to photon therapy. Sweden's new proton therapy facility, Skandionkliniken, is scheduled to being operation during August 2015, employing the pencil beam scanning technique. Given Skandionklinikens unique stance as the only facility offering proton therapy in Sweden as of this writing, it is important to minimize the need for measurements during quality assurance to free up beam time for patients and other endeavors. It is the purpose of this work to create a foundation for a method whereby dose distribution verification is done via Monte Carlo simulation by developing and performing simple validation of a beam model. As input for simulating a dose distribution, log files storing a wide variety of data on how the dose distribution was delivered were used.

Method: GATE, an open source Monte Carlo code and built on top of Geant4, was used for all simulations. A beam model parameterizing phase space at the nozzle exit was developed. The beam model development process made use of the beam data library and log file data. Using an in house developed code to convert log file data to treatment plans readable by GATE allowed simulation of delivered dose distributions. For validation, gamma index tests were performed comparing measured and simulated dose distributions.

Results: The beam model was found able to predict the spot size in almost all cases within 0.2 mm. Likewise, the beam model was able to predict the proton range within 0.2 mm. The energy spread was found to be more difficult to estimate; comparisons of simulated and measured curves for at six points around the Bragg peak yielded a maximum deviation of 0.86 mm. Several difficulties prevented easy interpretation of the results of the gamma index tests. If allowance is made for certain data manipulation, pass rates of 90% or above using the global method can be achieved for all depths and for both treatment plans scanned.

Conclusion: Although some complications arose during validation, the beam model performance appears capable of producing accurate results. To produce a full product suitable for routine patient specific quality assurance, further work will be necessary. Significant computing power would also be mandatory for routine use, necessitating the acquisition of a dedicated computer cluster or using GPUs.

Place, publisher, year, edition, pages
2015. , p. 81
National Category
Other Physics Topics
Identifiers
URN: urn:nbn:se:su:diva-123677OAI: oai:DiVA.org:su-123677DiVA, id: diva2:875796
Supervisors
Available from: 2018-04-04 Created: 2015-12-01 Last updated: 2018-04-04Bibliographically approved

Open Access in DiVA

fulltext(11172 kB)42 downloads
File information
File name FULLTEXT01.pdfFile size 11172 kBChecksum SHA-512
500490a781c281a440306bdf20049131a76c5d304b5c31dee3ddb1d05dd3e29d68a928e8a37f7177f440a60fc8b85b00f0be99ae0369378418036da60dc172ba
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Almhagen, Erik
By organisation
Department of Physics
Other Physics Topics

Search outside of DiVA

GoogleGoogle Scholar
Total: 42 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 631 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf