Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Determination of AZD6118 in dog plasma samples utilizing microextraction by packed sorbent and liquid chromatography-electrospray ionization tandem mass spectrometry
Stockholm University, Faculty of Science, Department of Environmental Science and Analytical Chemistry.
Stockholm University, Faculty of Science, Department of Environmental Science and Analytical Chemistry.
Stockholm University, Faculty of Science, Department of Environmental Science and Analytical Chemistry.ORCID iD: 0000-0002-3862-8878
Number of Authors: 32017 (English)In: Journal of chromatography. B, ISSN 1570-0232, E-ISSN 1873-376X, Vol. 1043, p. 20-24Article in journal (Refereed) Published
Abstract [en]

In this work, for the first time, a method has been developed for the determination of AZD6118, a candidate drug, in dog plasma samples. The method is based on microextraction by packed sorbent (MEPS) of the drug prior to liquid chromatography-electrospray ionization tandem mass spectrometry assay. Various important factors affecting MEPS performance were optimized, and under the optimized condition, a linear calibration curve in the concentration range of 20-25,000 nmol L-1 with a coefficient of determination over 0.99 was obtained. The back-calculated values of the calibration points showed good agreement with the theoretical concentrations (coefficients of variation percent between 0.3-3.8). The lower limit of quantification and limit of detection were 20.0 and 2.9 nmol L-1, respectively. The repeatability and accuracy of the method was evaluated by determination of quality control samples at three concentration levels (low, medium and high) using the developed method, and the results (coefficients of variation values were between 1.9% and 3.2%, relative recoveries ranged between 93.5-102.1%) confirm that a powerful method has been developed for the extraction and determination of the investigated drug in dog plasma.

Place, publisher, year, edition, pages
2017. Vol. 1043, p. 20-24
Keywords [en]
Microextraction by packed sorbent, AZD6118, Dog plasma samples, LC-ESI-MS/MS, Validation
National Category
Biological Sciences Chemical Sciences
Identifiers
URN: urn:nbn:se:su:diva-142539DOI: 10.1016/j.jchromb.2016.11.004ISI: 000395601900004PubMedID: 27836490OAI: oai:DiVA.org:su-142539DiVA, id: diva2:1093627
Available from: 2017-05-08 Created: 2017-05-08 Last updated: 2023-12-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

El Beqqali, AzizaAbdel-Rehim, Mohamed

Search in DiVA

By author/editor
El Beqqali, AzizaAbdel-Rehim, Mohamed
By organisation
Department of Environmental Science and Analytical Chemistry
In the same journal
Journal of chromatography. B
Biological SciencesChemical Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 100 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf