Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Impact of physiological breathing motion for breast cancer radiotherapy with proton beam scanning - An in silico study
Linköping University, Sweden.ORCID iD: 0000-0001-8425-8110
Stockholm University, Faculty of Science, Department of Physics.
Linköping University, Sweden.ORCID iD: 0000-0001-7193-4458
Stockholm University, Faculty of Science, Department of Physics. Karolinska Institutet, Sweden.ORCID iD: 0000-0002-7101-240X
Show others and affiliations
2017 (English)In: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 39, p. 88-94Article in journal (Refereed) Published
Abstract [en]

This study investigates the impact of breathing motion on proton breast treatment plans. Twelve patients with CT datasets acquired during breath-hold-at-inhalation (BHI), breath-hold-at-exhalation (BHE) and in free-breathing (FB) were included in the study. Proton plans were designed for the left breast for BHI and subsequently recalculated for BHE or designed for FB and recalculated for the extreme breath-hold phases. The plans were compared from the point of view of their target coverage and doses to organs-at-risk. The median amplitude of breathing motion determined from the positions of the sternum was 4.7 mm (range 0.5-14.6 mm). Breathing motion led to a degradation of the dose coverage of the target (heterogeneity index increased from 4-7% to 8-11%), but the degraded values of the dosimetric parameters of interest fulfilled the clinical criteria for plan acceptance. Exhalation decreased the lung burden [average dose 3.1-4.5 Gy (RBE)], while inhalation increased it [average dose 5.8-6.8 Gy (RBE)]. The individual values depended on the field arrangement. Smaller differences were seen for the heart [average dose 0.1-0.2 Gy (RBE)] and the LAD [1.9-4.6 Gy (RBE)]. Weak correlations were generally found between changes in dosimetric parameters and respiratory motion. The differences between dosimetric parameters for various breathing phases were small and their expected clinical impact is consequently quite small. The results indicated that the dosimetric parameters of the plans corresponding to the extreme breathing phases are little affected by breathing motion, thus suggesting that this motion might have little impact for the chosen beam orientations with scanned proton beams.

Place, publisher, year, edition, pages
2017. Vol. 39, p. 88-94
Keywords [en]
Breast radiotherapy, Proton radiotherapy, Scanned beam, Breathing motion
National Category
Cancer and Oncology
Identifiers
URN: urn:nbn:se:su:diva-144162DOI: 10.1016/j.ejmp.2017.06.001ISI: 000405493200012PubMedID: 28606833Scopus ID: 2-s2.0-85020442707OAI: oai:DiVA.org:su-144162DiVA, id: diva2:1108762
Available from: 2017-06-13 Created: 2017-06-13 Last updated: 2022-10-19Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Flejmer, Anna M.Josefsson, DanToma-Dasu, IulianaDasu, Alexandru

Search in DiVA

By author/editor
Flejmer, Anna M.Josefsson, DanToma-Dasu, IulianaDasu, Alexandru
By organisation
Department of Physics
In the same journal
Physica medica (Testo stampato)
Cancer and Oncology

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 124 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf