Inter-comparison of personal monitors for nanoparticles exposure at workplaces and in the environment
Show others and affiliations
Number of Authors: 222017 (English)In: Science of the Total Environment, ISSN 0048-9697, E-ISSN 1879-1026, Vol. 605, p. 929-945Article in journal (Refereed) Published
Abstract [en]

Personal monitors based on unipolar diffusion charging (miniDiSC/DiSCmini, NanoTracer, Partector) can be used to assess the individual exposure to nanoparticles in different environments. The charge acquired by the aerosol particles is nearly proportional to the particle diameter and, by coincidence, also nearly proportional to the alveolar lung-deposited surface area (LDSA), the metric reported by all three instruments. In addition, the miniDiSC/DiSCmini and the NanoTracer report particle number concentration and mean particle size. In view of their use for personal exposure studies, the comparability of these personal monitors was assessed in two measurement a large range of particle sizes, morphologies and concentrations. The data provided by the personal monitors were compared with those obtained from reference instruments: a scanning mobility particle sizer (SMPS) for LDSA and mean particle size and a ultrafine particle counter (UCPC) for number concentration. The results indicated that the LDSA concentrations and the mean particle sizes provided by all investigated instruments in this study were in the order of +/- 30% of the reference value obtained from the SMPS when the particle sizes of the test aerosols generated were within 20-400 nm and the instruments were properly calibrated. Particle size, morphology and concentration did not have a major effect within the aforementioned limits. The comparability of the number concentrations was found to be slightly worse and in the range of +/- 50% of the reference value obtained from the UCPC. In addition, a minor effect of the particle morphology on the number concentration measurements was observed. The presence of particles >400 nm can drastically bias the measurement results of all instruments and all metrics determined.

Place, publisher, year, edition, pages
2017. Vol. 605, p. 929-945
Keywords [en]
Personal monitors, Comparability, Alveolar lung deposited surface area concentration, Number concentration, Mean particle size
National Category
Earth and Related Environmental Sciences
Identifiers
URN: urn:nbn:se:su:diva-146939DOI: 10.1016/j.scitotenv.2017.06.041ISI: 000408275500097PubMedID: 28688352OAI: oai:DiVA.org:su-146939DiVA, id: diva2:1142576
Available from: 2017-09-19 Created: 2017-09-19 Last updated: 2025-02-07Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Elihn, KarineLidén, Göran

Search in DiVA

By author/editor
Elihn, KarineLidén, Göran
By organisation
Department of Environmental Science and Analytical ChemistryDepartment of Environmental Science
In the same journal
Science of the Total Environment
Earth and Related Environmental Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 41 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf