Development and validation of a UHPLC-HRMS method for the simultaneous determination of the endogenous anabolic androgenic steroids in human serum
Stockholm University, Faculty of Science, Department of Environmental Science and Analytical Chemistry.ORCID iD: 0000-0002-2485-4276
(English)Manuscript (preprint) (Other academic)
Abstract [en]

Being performance enhancing hormones, endogenous anabolic androgenic steroids (EAAS) are banned from most competitive sports by the World Anti-doping Agency (WADA).. In anti-doping control laboratories, routine assays are mainly performed on urine samples of athletes in and out of competitions. Serum constitutes a promising alternative to urine as it is less subjected to manipulation or contamination issues that may influence the method sensitivity. The simultaneous determination of EAAS and their conjugated metabolites is very challenging due to their contradicting chemical behaviors at the ionization interface of the mass spectrometer. This may prejudice their detection or limit the method sensitivity. Herein, we have addressed these challenges and developed a new method for the simultaneous determination of unconjugated, sulphate and glucuronide EAAS (Androsterone, Etiocholanolone, testosterone, epitestosterone, dihydrotestosterone, dehydroepiandrosterone, androstenedione and 17a-hydroxyprogesterone) in human serum using ultra-high performance liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS). The use of mass spectrometric detection in full scan mode facilitated the study of the most versatile adducts for detection and quantitation. Using solid phase extraction as sample preparation protocol prior to analysis, the method limits of quantitation ranged from 0.006 to 7.904 ng/mL and the recoveries ranged from 70.2 to 96.5 %. The method calibration was performed in untreated serum representing realistic matrix composition with correlation coeffecients ranged from 0.9859 to 0.9988. Finally, the serum- levels of the investigated steroids were determined in 4 male and 1 female human subject to provide estimates of baseline levels based on individual values.

Keywords [en]
Doping, Endogenous Anabolic androgenic steroids, Chromatography, UHPLC, Mass spectrometry, Solid phase extraction.
National Category
Analytical Chemistry
Research subject
Analytical Chemistry
Identifiers
URN: urn:nbn:se:su:diva-172564OAI: oai:DiVA.org:su-172564DiVA, id: diva2:1348245
Available from: 2019-09-03 Created: 2019-09-03 Last updated: 2019-09-04Bibliographically approved
In thesis
1.
The record could not be found. The reason may be that the record is no longer available or you may have typed in a wrong id in the address field.

Open Access in DiVA

No full text in DiVA

Search in DiVA

By author/editor
Elmongy, Hatem
By organisation
Department of Environmental Science and Analytical Chemistry
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 13 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf