Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The use of high resolution graphite furnace molecular absorption spectrometry (HR -MAS) for total fluorine determination in extractable organofluorines (EOF)
Stockholm University, Faculty of Science, Department of Environmental Science and Analytical Chemistry.ORCID iD: 0000-0002-3409-4389
Show others and affiliations
Number of Authors: 92020 (English)In: Talanta: The International Journal of Pure and Applied Analytical Chemistry, ISSN 0039-9140, E-ISSN 1873-3573, Vol. 209, article id 120466Article in journal (Refereed) Published
Abstract [en]

The determination of total fluorine content using high-resolution graphite furnace continuum source molecular absorption spectrometry (HR- MAS) has been employed in a variety of samples for over 10 years. However, most of the samples analysed by HR-MAS are rich in fluoride, with negligible levels of organic fluorinated species. With an increase in concern surrounding per- and polyfluoroalkyl substances (PFASs), new methods to measure total fluorine of organofluorine using different techniques have been developed. However, no studies focused on PFASs behaviour in HR-MAS have been performed. As these compounds encompass a wide range of different structures, boiling points, decomposition temperatures and matrix interactions, a loss of accuracy can occur when an aqueous external calibration is performed using only one compound. To overcome this issue, an investigation into permanent modifiers for the graphite furnace was performed. After optimisation similar sensitivity for different PFCA was achieved when 400 mu g of W was used as a permanent modifier together with an optimised temperature program. The relative deviation between the different PFCA standard slopes relative to the PFOA slope was lower than 15%. The instrumental limit of detection and quantification (LOD and LOQ, respectively) of total fluorine as total PFCA was 0.1 mg L-1 and 0.3 mg L-1, respectively, while the method LOD and LOQ (using solid phase extraction) was 0.3 mu g L-1 and 1.0 mu g L-1, respectively. The developed method gave satisfactory recoveries for the spiked PFCA into seawater, river water and effluent using PFOA calibration standards. The optimised method is useful for measuring extractable organofluorines (EOF) when only ionic PFASs such as PFCA are expected. When other organofluorines are expected, the results using HR GF-MAS should be taken with caution.

Place, publisher, year, edition, pages
2020. Vol. 209, article id 120466
Keywords [en]
Per- and polyfluoroalkyl substances, HR-MAS, Fluorine determination, POP, PFAS
National Category
Chemical Sciences
Identifiers
URN: urn:nbn:se:su:diva-179483DOI: 10.1016/j.talanta.2019.120466ISI: 000509632900015PubMedID: 31892068OAI: oai:DiVA.org:su-179483DiVA, id: diva2:1413646
Available from: 2020-03-10 Created: 2020-03-10 Last updated: 2022-02-26Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Schultes, LaraBenskin, Jonathan P.

Search in DiVA

By author/editor
Schultes, LaraBenskin, Jonathan P.
By organisation
Department of Environmental Science and Analytical Chemistry
In the same journal
Talanta: The International Journal of Pure and Applied Analytical Chemistry
Chemical Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 139 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf