Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A Novel Method to Maintain the Sample Position and Pressure in Differentially Pumped Systems Below the Resolution Limit of Optical Microscopy Techniques
Stockholm University, Faculty of Science, Department of Physics.ORCID iD: 0000-0002-0062-0643
Stockholm University, Faculty of Science, Department of Physics.
Stockholm University, Faculty of Science, Department of Physics.
Stockholm University, Faculty of Science, Department of Physics.
Show others and affiliations
Number of Authors: 72021 (English)In: Applied Spectroscopy, ISSN 0003-7028, E-ISSN 1943-3530, Vol. 75, no 2, p. 137-144Article in journal (Refereed) Published
Abstract [en]

We present a new method to maintain constant gas pressure over a sample during in situ measurements. The example shown here is a differentially pumped high-pressure X-ray photoelectron spectroscopy system, but this technique could be applied to many in situ instruments. By using the pressure of the differential stage as a feedback source to change the sample position, a new level of consistency has been achieved. Depending on the absolute value of the sample-to-aperture distance, this technique allows one to maintain the distance within several hundred nanometers, which is below the limit of typical optical microscopy systems. We show that this method is well suited to compensate for thermal drift. Thus, X-ray photoelectron spectroscopy data can be acquired continuously while the sample is heated and maintaining constant pressure over the sample. By implementing a precise manipulator feedback system, pressure variations of less than 5% were reached while the temperature was varied by 400 ℃. The system is also shown to be highly stable under significant changes in gas flow. After changing the flow by a factor of two, the pressure returned to the set value within 60 s.

Place, publisher, year, edition, pages
2021. Vol. 75, no 2, p. 137-144
Keywords [en]
Ambient pressure XPS, differentially pumped systems, constant distance, feedback loop, distance control, pressure control, proportional–, integral–, derivative loop, PID loop, in situ
National Category
Physical Sciences
Identifiers
URN: urn:nbn:se:su:diva-193280DOI: 10.1177/0003702820942798ISI: 000614542700002PubMedID: 32597682OAI: oai:DiVA.org:su-193280DiVA, id: diva2:1556344
Available from: 2021-05-21 Created: 2021-05-21 Last updated: 2022-02-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Goodwin, Christopher M.Alexander, John D.Weston, MatthewDegerman, DavidShipilin, MikhailAmann, Peter

Search in DiVA

By author/editor
Goodwin, Christopher M.Alexander, John D.Weston, MatthewDegerman, DavidShipilin, MikhailAmann, Peter
By organisation
Department of Physics
In the same journal
Applied Spectroscopy
Physical Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 35 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf