Monte Carlo Based Dose Verification for Serial Tomotherapy
Stockholm University, Faculty of Science, Medical Radiation Physics (together with KI).
Show others and affiliations
2007 (English)In: Proceedings in 49th AAPM Annual Meeting, Minneapolis, Minnesota, USA, July 22-26, 2007, 2007Conference paper, Published paper (Other academic)
Abstract [en]

Purpose: To develop a Monte Carlo model to verify the final dose distributions and monitor units for serial tomotherapy plans developed and delivered using the Peacock system (Corvus Treatment Planning System and MIMiC collimator, Nomos Corp., Sewickley, PA).

Materials and methods: The Peacock system delivers the dose to the patient using arc therapy. The treatment plan is created in Corvus were sinograms are created for each arc in order to dictate the state of each of the MIMiC leaves at different locations along the arc. In-house functions were written in Matlab (Mathworks Inc., Natick, MA) to decode these sinograms. A simple three-field plan (three gantry positions), as well as full patient treatment plans were simulated using our Monte Carlo model and the same plans were delivered using the Peacock system in solid water. Films were placed in the solid water phantom in order to measure the dose distribution for comparison against the Monte Carlo calculations. Matlab functions were written to convert the Monte Carlo output into a format RIT113 (RIT Inc., Colorado Springs, CO) could read. This allowed us to co-register the calculated dose maps and the measured ones in order to compare the two.

Results: The Monte Carlo calculated dose distribution from the complete arc therapy in solid water phantom was compared against film measurements. The agreement was within 2%. The comparison between Monte Carlo results and Corvus calculated dose distribution revealed that Corvus would fail to accurately compute the dose in the region where inhomogeneities were present.

Conclusions: Based on the agreement between Monte Carlo and measurements we can use the Monte Carlo system as an independent quality assurance tool in order to verify dose distributions and MUs per arc computed by the Corvus.

Place, publisher, year, edition, pages
2007.
Identifiers
URN: urn:nbn:se:su:diva-10817DOI: doi:10.1118/1.2760961OAI: oai:DiVA.org:su-10817DiVA: diva2:177336
Available from: 2008-01-07 Created: 2008-01-07 Last updated: 2010-03-25Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text
By organisation
Medical Radiation Physics (together with KI)

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 22 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf