Simultaneous determination of albumin and immunoglobulin G with fluorescence spectroscopy and multivariate calibration
Stockholm University, Faculty of Science, Department of Analytical Chemistry.
Stockholm University, Faculty of Science, Department of Analytical Chemistry.
2004 (English)In: Talanta: The International Journal of Pure and Applied Analytical Chemistry, ISSN 0039-9140, E-ISSN 1873-3573, Vol. 62, no 3, 567-574 p.Article in journal (Refereed) Published
Abstract [en]

A method is proposed for the simultaneous determination of albumin and immunoglobulin G (IgG1) with fluorescence spectroscopy and multivariate calibration with partial least squares regression (PLS). The influence of some instrumental parameters were investigated with two experimental designs comprising 19 and 11 experiments, respectively. The investigated parameters were excitation and emission slit, detection voltage and scan rate. When a suitable instrumental setting had been found, a minor calibration and test set were analysed and evaluated. Thereafter, a larger calibration of albumin and IgG1 was made out of 26 samples (0–42 μg ml−1 albumin and 0–12.7 μg ml−1 IgG1). This calibration was validated with a test set consisting of 14 samples in the same concentration range. The precision of the method was estimated by analysing two test set samples for six times each. The scan modes tested were emission scan and synchronous scan Δ60 nm. The results showed that the method could be used for determination of albumin and IgG1 (albumin, root mean square error of prediction (RMSEP) <2, relative standard error of prediction (RSEP) <6% and IgG1, RMSEP <1, RSEP <8%) in spite of the overlapping fluorescence of the two compounds. The estimated precision was relative standard deviation (R.S.D.) <1.7%. The method was finally applied for the analysis of some sample fractions from an albumin standard used in affinity chromatography.

Place, publisher, year, edition, pages
2004. Vol. 62, no 3, 567-574 p.
Keyword [en]
Determination, Albumin, Immunoglobulin G, Fluorescence spectroscopy, Multivariate calibration
Identifiers
URN: urn:nbn:se:su:diva-22776DOI: 10.1016/j.talanta.2003.08.024OAI: oai:DiVA.org:su-22776DiVA: diva2:189421
Note
Part of urn:nbn:se:su:diva-110Available from: 2004-04-22 Created: 2004-04-22 Last updated: 2017-12-13Bibliographically approved
In thesis
1. Multivariate spectroscopic methods for the analysis of solutions
Open this publication in new window or tab >>Multivariate spectroscopic methods for the analysis of solutions
2004 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

In this thesis some multivariate spectroscopic methods for the analysis of solutions are proposed. Spectroscopy and multivariate data analysis form a powerful combination for obtaining both quantitative and qualitative information and it is shown how spectroscopic techniques in combination with chemometric data evaluation can be used to obtain rapid, simple and efficient analytical methods. These spectroscopic methods consisting of spectroscopic analysis, a high level of automation and chemometric data evaluation can lead to analytical methods with a high analytical capacity, and for these methods, the term high-capacity analysis (HCA) is suggested. It is further shown how chemometric evaluation of the multivariate data in chromatographic analyses decreases the need for baseline separation.

The thesis is based on six papers and the chemometric tools used are experimental design, principal component analysis (PCA), soft independent modelling of class analogy (SIMCA), partial least squares regression (PLS) and parallel factor analysis (PARAFAC). The analytical techniques utilised are scanning ultraviolet-visible (UV-Vis) spectroscopy, diode array detection (DAD) used in non-column chromatographic diode array UV spectroscopy, high-performance liquid chromatography with diode array detection (HPLC-DAD) and fluorescence spectroscopy. The methods proposed are exemplified in the analysis of pharmaceutical solutions and serum proteins.

In Paper I a method is proposed for the determination of the content and identity of the active compound in pharmaceutical solutions by means of UV-Vis spectroscopy, orthogonal signal correction and multivariate calibration with PLS and SIMCA classification. Paper II proposes a new method for the rapid determination of pharmaceutical solutions by the use of non-column chromatographic diode array UV spectroscopy, i.e. a conventional HPLC-DAD system without any chromatographic column connected. In Paper III an investigation is made of the ability of a control sample, of known content and identity to diagnose and correct errors in multivariate predictions something that together with use of multivariate residuals can make it possible to use the same calibration model over time. In Paper IV a method is proposed for simultaneous determination of serum proteins with fluorescence spectroscopy and multivariate calibration. Paper V proposes a method for the determination of chromatographic peak purity by means of PCA of HPLC-DAD data. In Paper VI PARAFAC is applied for the decomposition of DAD data of some partially separated peaks into the pure chromatographic, spectral and concentration profiles.

Place, publisher, year, edition, pages
Stockholm: Institutionen för analytisk kemi, 2004. 73 p.
Keyword
Chemometrics, UV-Vis spectroscopy, Multivariate calibration, Lidocaine, Identity, Content, PLS, SIMCA, Non-column, Diode array UV spectroscopy, DAD, Control sample, High Capacity Analysis (HCA), Fluorescence spectroscopy, Albumin, Immunoglobulin G, HPLC-DAD, Prilocaine, Peak purity determination, PCA, PARAFAC, Partial separation, Curve resolution
National Category
Analytical Chemistry
Identifiers
urn:nbn:se:su:diva-110 (URN)91-7265-789-8 (ISBN)
Public defence
2004-05-14, Magnélisalen, Kemiska övningslaboratoriet, Svante Arrhenius väg 12 A, Stockholm, 13:15
Opponent
Supervisors
Available from: 2004-04-22 Created: 2004-04-22Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Jacobsson, Sven P.
By organisation
Department of Analytical Chemistry
In the same journal
Talanta: The International Journal of Pure and Applied Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 54 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf