Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Prostate brachytherapy: Pre-plan and real-time transperineal ultrasound guided Iodine-125 permanent seed implants at Södersjukhuset, Karolinska University Hospital.
Stockholm University, Faculty of Science, Medical Radiation Physics (together with KI).
2008 (English)Independent thesis Basic level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Purpose: The aim of this thesis is to study the European (ESTRO/EAU/EORTC) and American (ABS) guidelines how to report the permanent seed implant and the most significant dosimetric parameters. It will also report on the permanent seed implant at Södersjukhuset, Karolinska University Hospital according to the guidelines. A large number of studies on pre- and post-implant dosimetry on permanent seed implants have recently been published but none is considered a standard. This makes it difficult, if not impossible, to compare data from different centres. The differences in reporting will also be discussed in this thesis. Another part of the study is to investigate how the morbidity correlates with the dose. The results in this report will give an overview of the experience at Södersjukhuset.

Matherials and Methods: This study includes 198 patients who received implants between 2004-2007 with I-125 seeds under transperineal ultrasound at Södersjukhuset (to a prescribed dose of 145 Gy). The dose-planning system VariSeed 7.1 was used with an online connection to the ultrasound system with real-time verification. Dose constraints for the planning system are V(100)>99%, V(150)>60%, V(200)>25%, UrD(10)<130% and UrD(30)<125%. Outer and inner wall of rectum was outlined for 55 patients as recommended by ESTRO/EAU/EORTC and doses to rectum were also computed.

Results: The median value for dosimetric parameters at Södersjukhuset, Karolinska University Hospital are for the prostate; D(90)=174Gy (153-194Gy), V(100)= 99% (93-100%), V(150)= 57% (40-74%), for the urethra; UrD(30) = 130% (112-147%), UrD(10) = 124% (107-142%) and for the rectum; RD2cc= 98Gy (73-128Gy), RD0.1cc=164Gy (119-240Gy), RV(100)=0.3cc (0.0-1.3cc), RV(150)=0.0cc (0.0-0.2cc). These values correspond to recommended data, except for the V(150) value. Regarding the clinically observed results, 3 patients had a relapse in their cancer, 2 patients had mild proctitis and 15 patients had urinary problems.

Discussion and Conclusions: The significant dosimetric parameters for reporting according to ESTRO/EAU/EORTC and ABS for prostate are D90[Gy], V(100)[%] and V(150)[%], for urethra are D(30) and D(10), and for rectum RD2cc and RD0.1cc. These parameters consider as a minimum to use and they further recommend secondary parameters to report. Other authors have also recommended to report RV(100) and RV(150) for rectum. This study did not show any relationship between UrD(10), UrD(30) and urinary morbidity. According to the recommendations every patient should undergo a CT-based evaluation. Further investigations are needed on whether a post-implant CT-study is necessary for real-time implantation, as there is not enough published data on this aspect.

Place, publisher, year, edition, pages
2008. , 38 p.
Keyword [en]
Brachytherapy, Iodine-125, Permanent seed implant, Guidelines, Intraoperative planning, Real-time
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:su:diva-8299OAI: oai:DiVA.org:su-8299DiVA: diva2:200017
Presentation
2008-06-23
Uppsok
medicin
Supervisors
Examiners
Available from: 2008-10-28 Created: 2008-10-28Bibliographically approved

Open Access in DiVA

fulltext(480 kB)983 downloads
File information
File name FULLTEXT01.pdfFile size 480 kBChecksum SHA-1
e55c73f8aab494e1845755ddf3da8018331e773fde9f534e9f23b9ad344c205567a6811f
Type fulltextMimetype application/pdf

By organisation
Medical Radiation Physics (together with KI)
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 983 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 408 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf