Change search
ReferencesLink to record
Permanent link

Direct link
Comparison of the 3D-conformal, helical tomotherapy and multileaf collimators-based intensity modulated radiotherapy modalities using radiobiological measures
Stockholm University.
Stockholm University.
Show others and affiliations
2008 (English)In: JOURNAL OF BUON, ISSN 1107-0625, Vol. 13, no 1, 75-86 p.Article in journal (Refereed) Published
Abstract [en]

Purpose: Intensity modulated radiotherapy (IMRT) using multileaf collimators (MLC) and helical tomotherapy (HT) have become increasingly popular over the past few years. However their clinical efficacy and effectiveness continue to be investigated. In order to provide a more thorough evaluation and comparison of treatment plans, the utilization of the biologically effective uniform dose (D) together with the complication-free tumor control probability (P+) are examined. Materials and methods:In this study, a typical case of lung cancer was investigated by developing a 3D conformal treatment plan, a linac MLC-based step-and-shoot IMRT plan and a HT plan. The 3 different treatment plans were compared based on radiobiological measures by using the P+ index and the D concept as the common prescription point of the plans and plotting the tissue response probabilities vs. D for a range of prescription doses. Results: The applied plan evaluation method showed that in this lung cancer case the MLC-based IMRT plan was best over the clinically useful dose prescription range. The 3D-conformal, MLC-based IMRT and HT treatment plans gave a P+ of 55.4%, 72.9% and 66.9%, for a D to the internal target volume (ITV) of 57.0 Gy, 66.9 Gy and 64.0 Gy, respectively. Conclusion: In comparison to 3D conformal radiotherapy, both Affi based-IMRT and HT can better encompass the often large ITV required while minimizing the volume of the organs at risk receiving high dose. Taking into account the dose-response relations of the irradiated tumors and normal tissues, a radiobiological treatment plan evaluation can be performed, which may provide a closer association of the delivered treatment with the clinical outcome.

Place, publisher, year, edition, pages
2008. Vol. 13, no 1, 75-86 p.
Keyword [en]
biologically effective uniform dose, conformal radiotherapy, complication-free tumor control, dose-response relations, helical tomotherapy, radiobiological evaluation
URN: urn:nbn:se:su:diva-58558ISI: 000256591700012OAI: diva2:421251
authorCount :5Available from: 2011-06-08 Created: 2011-06-03 Last updated: 2011-06-08Bibliographically approved

Open Access in DiVA

No full text

By organisation
Stockholm University

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 15 hits
ReferencesLink to record
Permanent link

Direct link