Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Nanodosimetry in a (12)C ion beam using Monte Carlo simulations
Stockholm University, Faculty of Science, Department of Physics.
Stockholm University, Faculty of Science, Department of Physics.
Show others and affiliations
2010 (English)In: Radiation Measurements, ISSN 1350-4487, E-ISSN 1879-0925, Vol. 45, no 10, 1238-1241 p.Article in journal (Refereed) Published
Abstract [en]

The dose-mean lineal energy, (y) over bar (D), has been calculated in water for irradiation with (12)C ions with initial energies 290 MeV/u. The y, was evaluated from the energy distributions of carbon and secondary boron ions, and from their energy-dependent pp-values. The energy distributions were obtained from simulations with the Monte Carlo code SHIELD-HIT07 and the energy-dependent (y) over bar (D)-values were obtained from ion-track simulations with PITS99 coupled with the electron transport code KURBUC. The ratio of the (y) over bar (D)-value determined in the vicinity of the Bragg peak to that calculated in a reference (60)Co gamma beam was compared with the corresponding ratio of alpha-values from the linear-quadratic model used in fractionated radiotherapy, showing a good correlation for an object size of around 10 nm.

Place, publisher, year, edition, pages
2010. Vol. 45, no 10, 1238-1241 p.
Keyword [en]
Microdosimetry, Nanodosimetry, Carbon ion radiotherapy, Monte Carlo simulation
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:su:diva-66241DOI: 10.1016/j.radmeas.2010.05.033ISI: 000286349000038OAI: oai:DiVA.org:su-66241DiVA: diva2:467416
Note
authorCount :5Available from: 2011-12-19 Created: 2011-12-19 Last updated: 2017-12-08Bibliographically approved
In thesis
1. Secondary absorbed dose distributions and radiation quality in light ion therapy
Open this publication in new window or tab >>Secondary absorbed dose distributions and radiation quality in light ion therapy
2011 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Radiotherapy with light ions offers the possibility of achieving a dose distribution which is highly conformed to the target volume while sparing normal tissues. For ions heavier than protons, an additional advantage is the increased Relative Biological Effectiveness (RBE) as compared to conventional photon and electron beams. During light ion therapy, nuclear fragments are produced in nuclear inelastic collisions of the projectile and the atomic nuclei in the material. In a cascade of events, the nuclear fragments in turn produce secondaries during their transport. The organs of the patient are thus exposed to a complex secondary radiation field and secondary doses can be delivered to normal tissues both close to and relatively far from the treated volume. In this thesis, secondary doses were evaluated in anthropomorphic phantoms which were developed for simulations with the Monte Carlo code SHIELD-HIT. Simulations of lung tumor, prostate and brain tumor irradiation with 1H, 4He, 7Li, 12C and 16O ion beams in the energy range 80-400 MeV/u were performed with SHIELD-HIT. The simulated organ absorbed doses were in the range 10-6-10-1 mGy per treatment Gy. In general, the organ absorbed doses decreased with increasing distance from the target volume and increased with increasing atomic number of the primary ions.

The produced nuclear fragments also influences the radiation quality in the target volume and thus the biological effectiveness of the beam. The dose-mean lineal energy, <yD>, was studied in a 290 MeV/u 12C beam by simulating the energy distributions of both primary and secondary ions and weighting their relative dose fractions with the corresponding energy-dependent <yD> which were obtained by ion-track simulations with PITS99 coupled with the electron transport code KURBUC. <yD> were evaluated in the target volume for object diameters 10-100 nm and were used in estimations of clinically useful weighting factors.

Place, publisher, year, edition, pages
Stockholm: Department of Physics, Stockholm University, 2011. 54 p.
Keyword
secondary doses, light ion therapy, radiation quality, Monte Carlo simulation
National Category
Physical Sciences
Research subject
Medical Radiation Physics
Identifiers
urn:nbn:se:su:diva-64302 (URN)978-91-7447-412-1 (ISBN)
Public defence
2011-12-20, Föreläsningssalen, Cancercentrum Karolinska, R8:00, Karolinska universitetssjukhuset, Solna, 13:00 (English)
Opponent
Supervisors
Note

At the time of the doctoral defense, the following paper was unpublished and had a status as follows: Paper 4: Submitted.

Available from: 2011-11-28 Created: 2011-11-16 Last updated: 2016-01-18Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Hultqvist, MarthaGudowska, Irena
By organisation
Department of Physics
In the same journal
Radiation Measurements
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 55 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf