Performance of independent dose calculation in helical tomotherapy: implementation of the mcsim code
Stockholm University, Faculty of Science, Department of Physics.
Show others and affiliations
2012 (English)In: Australasian Physical & Engineering Sciences in Medicine, ISSN 0158-9938, Vol. 35, no 4, 423-438 p.Article in journal (Refereed) Published
Abstract [en]

Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used to convert HT treatment plan information into a non-helical format. The MCSIM dose calculation code was evaluated by comparing point dose calculations and dose profiles against those from the HT treatment plan. Fifteen patients, representing five treatment sites, were used in this comparison. Point dose calculations between the HT treatment planning system and the EGS4/MCSIM Monte Carlo environment had percent difference values below 5 % for the majority of this study. Vertical and horizontal planar profiles also had percent difference values below 5 % for the majority of this study. Down sampling was seen to improve speed without much loss of accuracy. EGS4/MCSIM Monte Carlo environment showed good agreement with point dose measurements, compared to the HT treatment plans. Vertical and horizontal profiles also showed good agreement. Significant time saving may be obtained by down-sampling beam projections. The dose calculation accuracy of the in-house software using the MCSIM code against the treatment planning system calculations was evaluated. By comparing point doses and dose profiles, the EGS4/MCSIM Monte Carlo environment was seen to provide an accurate independent dose calculation.

Place, publisher, year, edition, pages
2012. Vol. 35, no 4, 423-438 p.
Keyword [en]
Independent dose calculation, Helical tomotherapy, Implementation, MCSIM code
National Category
Biomedical Laboratory Science/Technology
Identifiers
URN: urn:nbn:se:su:diva-88297DOI: 10.1007/s13246-012-0165-xISI: 000314407000006OAI: oai:DiVA.org:su-88297DiVA: diva2:612174
Note

AuthorCount:5;

Available from: 2013-03-20 Created: 2013-03-12 Last updated: 2013-03-20Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Mavroidis, Panayiotis
By organisation
Department of Physics
Biomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 28 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf