Evaluation of microextraction by packed sorbent and micro-liquid chromatography-tandem mass spectrometry as a green approach in bioanalysis
Stockholm University, Faculty of Science, Department of Analytical Chemistry.
Stockholm University, Faculty of Science, Department of Analytical Chemistry.
2013 (English)In: BMC Biomedical chromotography, ISSN 0269-3879, E-ISSN 1099-0801, Vol. 27, no 10, 1225-1233 p.Article in journal (Refereed) Published
Abstract [en]

In this study the use of micro-liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) was investigated in routine bioanalysis application for separation and quantification of pro-drug AZD6319 (developed for aldezheimer treatment). Microextraction by packed sorbent (MEPS) was used as sample clean-up method. The focus of this study was put on the evaluation of the usability of smaller column diameters such as 1.0 and 0.3mm instead of 2.1mm in bioanalysis application to reduce solvent consumption and sample volumes. Solvent consumption was reduced by 80% when a 1.0mm column was used compared with 2.1mm column. Robustness of the micro-columns in terms of accuracy and precision was investigated. The application of LC-MS/MS for the quantitative analysis of AZD6319 in plasma samples showed good selectivity, accuracy and precision. The coefficients of determination (R-2) were >0.998 for all runs using plasma samples on the studied micro-columns. The inter-day accuracy values for quality control samples ranged from 99 to 103% and from 96 to 105% for 0.3x50mm and 1.0x50mm columns, respectively. The inter-day precision values ranged from 4.0 to 9.0% and from 4.0 to 8.0% for 0.3x50 and 1.0x50mm columns, respectively. In addition the sensitivity was increased by three times using a 1.0mm column compared with 2.1mm. Furthermore, robustness of the micro-columns from different manufacturers was investigated.

Place, publisher, year, edition, pages
2013. Vol. 27, no 10, 1225-1233 p.
Keyword [en]
microextraction by packed sorbent, micro-LC columns, plasma samples, green bioanalysis
National Category
Biochemistry and Molecular Biology Analytical Chemistry
URN: urn:nbn:se:su:diva-94018DOI: 10.1002/bmc.2839ISI: 000323900600001OAI: diva2:651846


Available from: 2013-09-27 Created: 2013-09-24 Last updated: 2013-09-27Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Abdel-Rehim, Mohamed
By organisation
Department of Analytical Chemistry
In the same journal
BMC Biomedical chromotography
Biochemistry and Molecular BiologyAnalytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 190 hits
ReferencesLink to record
Permanent link

Direct link