Abstract [en]

Purpose: To assess the efficacy of the BLADE technique (MR imaging with 'rotating blade-like k-space covering') to significantly reduce motion, truncation, flow and other artifacts in cervical spine compared to the conventional technique. Materials and methods: In eighty consecutive subjects, who had been routinely scanned for cervical spine examination, the following pairs of sequences were compared: a) T2 TSE SAG vs. T2 TSE SAG BLADE and b) T2 TIRM SAG vs. T2 TIRM SAG BLADE. A quantitative analysis was performed using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measures. A qualitative analysis was also performed by two radiologists, who graded seven image characteristics on a 5-point scale (0: non-visualization; 1: poor; 2: average; 3: good; 4: excellent). The observers also evaluated the presence of image artifacts (motion, truncation, flow, indentation). Results: In quantitative analysis, the CNR values of the CSF/SC between TIRM SAG and TIRM SAG BLADE were found to present statistically significant differences (p < 0.001). Regarding motion and truncation artifacts, the T2 TSE BLADE SAG was superior compared to the T2 TSE SAG, and the T2 TIRM BLADE SAG was superior compared to the T2 TIRM SAG. Regarding flow artifacts, T2 TIRM BLADE SAG eliminated more artifacts than T2 TIRM SAG. Conclusions: In cervical spine MRI, BLADE sequences appear to significantly reduce motion, truncation and flow artifacts and improve image quality. BLADE sequences are proposed to be used for uncooperative subjects. Nevertheless, more research needs to be done by testing additional specific pathologies.

Place, publisher, year, edition, pages
2015. Vol. 33, no 2, 194-200 p.
Keyword [en]
Cervical spine MR imaging, BLADE sequences, Image quality, Artifact reduction
National Category
Radiology, Nuclear Medicine and Medical Imaging
URN: urn:nbn:se:su:diva-115695DOI: 10.1016/j.mri.2014.10.014ISI: 000349738900002PubMedID: 25461304OAI: diva2:799301


Available from: 2015-03-30 Created: 2015-03-27 Last updated: 2015-03-30Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed
By organisation
Department of Physics
In the same journal
Magnetic Resonance Imaging
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 18 hits
ReferencesLink to record
Permanent link

Direct link