Change search
ReferencesLink to record
Permanent link

Direct link
Online post-column solvent assisted and direct solvent-assisted electrospray ionization for chiral analysis of propranolol enantiomers in plasma samples
Stockholm University, Faculty of Science, Department of Environmental Science and Analytical Chemistry. Damanhour University, Egypt.
Show others and affiliations
Number of Authors: 5
2015 (English)In: Journal of Chromatography A, ISSN 0021-9673, E-ISSN 1873-3778, Vol. 1418, 110-118 p.Article in journal (Refereed) Published
Abstract [en]

An Online post-column solvent-assisted ionization (OPSAI) method was developed for enhancing the ionization of the beta-blocker propranolol utilizing normal phase LC-MS/MS. Solvent-assisted electrospray ionization (SAESI) was studied by the introduction of the assistant solvents A: 0.5% Formic acid in Isopropanolol, B: 0.5% Formic acid in lsopropanolol-Water (1:1), and C: 0.5% Formic acid in water into the electrospray ionization chamber using a spray needle. Analyte molecules can be directly ionized by the aid of the assistant solvent spray. Both methods were applied to the chiral separation of propranolol enantiomers using normal phase analysis on cellulose-based chiral column. Interestingly, both methods are easy to handle and offer a wide range of assistant solvents that can be used in order to gain the optimum ionization of the analyte molecules. The both methods considerably improved the analyte signal and the peak area greatly increased. The propranolol average signal-to-noise (S/N) ratio was enhanced from 26 +/- 1 and 42 +/- 1 to 2341 +/- 61 and 1725 +/- 29 for R-propranolol and S-propranolol, respectively, when the post-column solvent method (OPSAI) was used with isopropanol-assistant solvent (A). While in case of solvent-assisted electrospray ionization method (SAESI) signal was enhanced from 26 +/- 1 and 42 +/- 1 to 2223 +/- 72 and 2155 +/- 58 for R-propranolol and S-propranolol, respectively, with water as an assistant solvent. The limit of detection was 10 ng/mL and the method was linear in the range 50-2000 ng/mL. The NPLC-MS method was applied for the determination of propranolol enantiomers in human plasma after microextraction by packed C18 sorbent.

Place, publisher, year, edition, pages
2015. Vol. 1418, 110-118 p.
Keyword [en]
Normal phase LC, Chiral separation, Propranolol Enantiomers, Electrospray ionization, Tandem mass spectrometry
National Category
Biological Sciences Chemical Sciences
Identifiers
URN: urn:nbn:se:su:diva-123792DOI: 10.1016/j.chroma.2015.09.051ISI: 000364268200012PubMedID: 26422307OAI: oai:DiVA.org:su-123792DiVA: diva2:882633
Available from: 2015-12-15 Created: 2015-12-07 Last updated: 2015-12-15Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Elmongy, HatemAbdel-Rehim, Mohamed
By organisation
Department of Environmental Science and Analytical Chemistry
In the same journal
Journal of Chromatography A
Biological SciencesChemical Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 18 hits
ReferencesLink to record
Permanent link

Direct link