Change search
Refine search result
1 - 6 of 6
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the Create feeds function.
  • 1.
    Gatchell, Michael
    et al.
    Stockholm University, Faculty of Science, Department of Physics.
    Schmidt, Henning T.
    Stockholm University, Faculty of Science, Department of Physics.
    Alexander, John D.
    Stockholm University, Faculty of Science, Department of Physics.
    Andler, Guillermo
    Stockholm University, Faculty of Science, Department of Physics.
    Björkhage, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Blom, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Brännholm, Lars
    Stockholm University, Faculty of Science, Department of Physics.
    Bäckström, Erik
    Stockholm University, Faculty of Science, Department of Physics.
    Chen, Tao
    Stockholm University, Faculty of Science, Department of Physics.
    Geppert, Wolf
    Stockholm University, Faculty of Science, Department of Physics.
    Halldén, Per
    Stockholm University, Faculty of Science, Department of Physics.
    Hanstorp, Dag
    Hellberg, Fredrik
    Stockholm University, Faculty of Science, Department of Physics.
    Källberg, Anders
    Stockholm University, Faculty of Science, Department of Physics.
    Larsson, Mats
    Stockholm University, Faculty of Science, Department of Physics.
    Leontein, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Liljeby, Leif
    Stockholm University, Faculty of Science, Department of Physics.
    Löfgren, Patrik
    Stockholm University, Faculty of Science, Department of Physics.
    Mannervik, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Paal, Andras
    Stockholm University, Faculty of Science, Department of Physics.
    Reinhed, Peter
    Stockholm University, Faculty of Science, Department of Physics.
    Rensfelt, Karl-Gunnar
    Stockholm University, Faculty of Science, Department of Physics.
    Rosén, Stefan
    Stockholm University, Faculty of Science, Department of Physics.
    Seitz, Fabian
    Stockholm University, Faculty of Science, Department of Physics.
    Simonsson, Ansgar
    Stockholm University, Faculty of Science, Department of Physics.
    Stockett, Mark H.
    Stockholm University, Faculty of Science, Department of Physics.
    Thomas, Richard D.
    Stockholm University, Faculty of Science, Department of Physics.
    Zettergren, Henning
    Stockholm University, Faculty of Science, Department of Physics.
    Cederquist, Henrik
    Stockholm University, Faculty of Science, Department of Physics.
    First results from the Double ElectroStatic Ion-Ring ExpEriment, DESIREE2014In: Journal of Physics, Conference Series, ISSN 1742-6588, E-ISSN 1742-6596, Vol. 488, p. 092003-Article in journal (Refereed)
    Abstract [en]

    We have stored the first beams in one of the rings of the double electrostatic ion-storage ring, DESIREE at cryogenic and at room temperature conditions. At cryogenic operations the following parameters are found. Temperature; T= 13K, pressure; p <10(-13) mbar, initial number of stored ions; N > 10(7) and storage lifetime of a C-2(-) beam; tau = 450 S.

  • 2.
    Gatchell, Michael
    et al.
    Stockholm University, Faculty of Science, Department of Physics.
    Schmidt, Henning T.
    Stockholm University, Faculty of Science, Department of Physics.
    Thomas, Richard D.
    Stockholm University, Faculty of Science, Department of Physics.
    Rosén, Stefan
    Stockholm University, Faculty of Science, Department of Physics.
    Reinhed, Peter
    Stockholm University, Faculty of Science, Department of Physics.
    Löfgren, Patrik
    Stockholm University, Faculty of Science, Department of Physics.
    Brännholm, Lars
    Stockholm University, Faculty of Science, Department of Physics.
    Blom, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Björkhage, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Bäckström, Erik
    Stockholm University, Faculty of Science, Department of Physics.
    Alexander, John D.
    Stockholm University, Faculty of Science, Department of Physics.
    Leontein, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Hanstorp, D.
    Zettergren, Henning
    Stockholm University, Faculty of Science, Department of Physics.
    Liljeby, Leif
    Stockholm University, Faculty of Science, Department of Physics.
    Källberg, Anders
    Stockholm University, Faculty of Science, Department of Physics.
    Simonsson, Ansgar
    Stockholm University, Faculty of Science, Department of Physics.
    Hellberg, Fredrik
    Stockholm University, Faculty of Science, Department of Physics.
    Mannervik, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Larsson, Mats
    Stockholm University, Faculty of Science, Department of Physics.
    Geppert, Wolf D.
    Stockholm University, Faculty of Science, Department of Physics.
    Rensfelt, Karl-Gunnar
    Stockholm University, Faculty of Science, Department of Physics.
    Danared, Håkan
    Stockholm University, Faculty of Science, Department of Physics. European Spallation Source, Sweden.
    Paál, Andras
    Stockholm University, Faculty of Science, Department of Physics.
    Masuda, Masaharu
    Stockholm University, Faculty of Science, Department of Physics.
    Halldén, Per
    Stockholm University, Faculty of Science, Department of Physics.
    Andler, Guillermo
    Stockholm University, Faculty of Science, Department of Physics.
    Stockett, Mark H.
    Stockholm University, Faculty of Science, Department of Physics.
    Chen, Tao
    Stockholm University, Faculty of Science, Department of Physics.
    Källersjö, Gunnar
    Stockholm University, Faculty of Science, Department of Physics.
    Weimer, Jan
    Stockholm University, Faculty of Science, Department of Physics.
    Hansen, K.
    Hartman, H.
    Cederquist, Henrik
    Stockholm University, Faculty of Science, Department of Physics.
    Commissioning of the DESIREE storage rings - a new facility for cold ion-ion collisions2014In: Journal of Physics, Conference Series, ISSN 1742-6588, E-ISSN 1742-6596, Vol. 488, p. 012040-Article in journal (Refereed)
    Abstract [en]

    We report on the ongoing commissioning of the Double ElectroStatic Ion Ring ExpEriment, DESIREE, at Stockholm University. Beams of atomic carbon anions (C-) and smaller carbon anion molecules (C-2(-), C-3(-), C-4(-) etc.) have been produced in a sputter ion source, accelerated to 10 keV or 20 keV, and stored successfully in the two electrostatic rings. The rings are enclosed in a common vacuum chamber cooled to below 13 Kelvin. The DESIREE facility allows for studies of internally relaxed single isolated atomic, molecular and cluster ions and for collision experiments between cat-and anions down to very low center-of-mass collision energies (meV scale). The total thermal load of the vacuum chamber at this temperature is measured to be 32 W. The decay rates of stored ion beams have two components: a non-exponential component caused by the space charge of the beam itself which dominates at early times and an exponential term from the neutralization of the beam in collisions with residual gas at later times. The residual gas limited storage lifetime of carbon anions in the symmetric ring is over seven minutes while the 1/e lifetime in the asymmetric ring is measured to be about 30 seconds. Although we aim to improve the storage in the second ring, the number of stored ions are now sufficient for many merged beams experiments with positive and negative ions requiring milliseconds to seconds ion storage.

  • 3.
    Schmidt, Henning T.
    et al.
    Stockholm University, Faculty of Science, Department of Physics.
    Thomas, Richard D.
    Stockholm University, Faculty of Science, Department of Physics.
    Gatchell, Michael
    Stockholm University, Faculty of Science, Department of Physics.
    Rosén, Stefan
    Stockholm University, Faculty of Science, Department of Physics.
    Reinhed, Peter
    Stockholm University, Faculty of Science, Department of Physics.
    Löfgren, Patrik
    Stockholm University, Faculty of Science, Department of Physics.
    Brännholm, Lars
    Stockholm University, Faculty of Science, Department of Physics.
    Blom, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Björkhage, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Bäckström, Erik
    Stockholm University, Faculty of Science, Department of Physics.
    Alexander, John D.
    Stockholm University, Faculty of Science, Department of Physics.
    Leontein, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Hanstorp, D.
    Zettergren, Henning
    Stockholm University, Faculty of Science, Department of Physics.
    Liljeby, Leif
    Stockholm University, Faculty of Science, Department of Physics.
    Källberg, Anders
    Stockholm University, Faculty of Science, Department of Physics.
    Simonsson, Ansgar
    Stockholm University, Faculty of Science, Department of Physics.
    Hellberg, Fredrik
    Stockholm University, Faculty of Science, Department of Physics.
    Mannervik, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Larsson, Mats
    Stockholm University, Faculty of Science, Department of Physics.
    Geppert, Wolf D.
    Stockholm University, Faculty of Science, Department of Physics.
    Rensfelt, Karl-Gunnar
    Stockholm University, Faculty of Science, Department of Physics.
    Danared, Håkan
    Stockholm University, Faculty of Science, Department of Physics.
    Paal, A.
    Stockholm University, Faculty of Science, Department of Physics.
    Masuda, Masaharu
    Stockholm University, Faculty of Science, Department of Physics.
    Hallden, Per
    Stockholm University, Faculty of Science, Department of Physics.
    Andler, Guillermo
    Stockholm University, Faculty of Science, Department of Physics.
    Stockett, Mark H.
    Stockholm University, Faculty of Science, Department of Physics.
    Chen, Tao
    Stockholm University, Faculty of Science, Department of Physics.
    Källersjö, Gunnar
    Stockholm University, Faculty of Science, Department of Physics.
    Weimer, Jan
    Stockholm University, Faculty of Science, Department of Physics.
    Hansen, K.
    Hartman, H.
    Cederquist, Henrik
    Stockholm University, Faculty of Science, Department of Physics.
    First storage of ion beams in the Double Electrostatic Ion-Ring Experiment: DESIREE2013In: Review of Scientific Instruments, ISSN 0034-6748, E-ISSN 1089-7623, Vol. 84, no 5, p. 055115-Article in journal (Refereed)
    Abstract [en]

    We report on the first storage of ion beams in the Double ElectroStatic Ion Ring ExpEriment, DESIREE, at Stockholm University. We have produced beams of atomic carbon anions and small carbon anion molecules (C-n(-), n = 1, 2, 3, 4) in a sputter ion source. The ion beams were accelerated to 10 keV kinetic energy and stored in an electrostatic ion storage ring enclosed in a vacuum chamber at 13 K. For 10 keV C-2(-) molecular anions we measure the residual-gas limited beam storage lifetime to be 448 s +/- 18 s with two independent detector systems. Using the measured storage lifetimes we estimate that the residual gas pressure is in the 10(-14) mbar range. When high current ion beams are injected, the number of stored particles does not follow a single exponential decay law as would be expected for stored particles lost solely due to electron detachment in collision with the residual-gas. Instead, we observe a faster initial decay rate, which we ascribe to the effect of the space charge of the ion beam on the storage capacity.

  • 4.
    Schmidt, Henning
    et al.
    Stockholm University, Faculty of Science, Department of Physics.
    Johansson, Henrik
    Stockholm University, Faculty of Science, Department of Physics.
    Thomas, Richard
    Stockholm University, Faculty of Science, Department of Physics.
    Geppert, Wolf
    Stockholm University, Faculty of Science, Department of Physics.
    Haag, Nicole
    Stockholm University, Faculty of Science, Department of Physics.
    Reinhed, Peter
    Stockholm University, Faculty of Science, Department of Physics.
    Rosén, Stefan
    Stockholm University, Faculty of Science, Department of Physics.
    Larsson, Mats
    Stockholm University, Faculty of Science, Department of Physics.
    Danared, Håkan
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Rensfelt, K.-G
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Liljeby, Leif
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Bagge, Lars
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Björkhage, Mikael
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Blom, Mikael
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Löfgren, Patrik
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Källberg, Anders
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Simonsson, Ansgar
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Paál, Andras
    Stockholm University, Faculty of Science, The Manne Siegbahn Laboratory .
    Zettergren, Henning
    Stockholm University, Faculty of Science, Department of Physics.
    Cederquist, Henrik
    Stockholm University, Faculty of Science, Department of Physics.
    DESIREE as a new tool for interstellar ion chemistry2008In: International Journal of Astrobiology, ISSN 1473-5504, E-ISSN 1475-3006, Vol. 7, no 3-4, p. 205-208Article in journal (Refereed)
    Abstract [en]

    A novel cryogenic electrostatic storage device consisting of two ion-beam storage rings with a common straight section for studies of interactions between oppositely charged ions at low and well-defined relative velocities is under construction at Stockholm University. Here we consider the prospect of using this new tool to measure cross-sections and rate coefficients for mutual neutralization reactions of importance in interstellar ion chemistry in general and specifically in cosmic pre-biotic ion chemistry.

  • 5.
    Thomas, Richard D.
    et al.
    Stockholm University, Faculty of Science, Department of Physics.
    Schmidt, Henning T.
    Stockholm University, Faculty of Science, Department of Physics.
    Andler, Guillermo
    Stockholm University, Faculty of Science, Department of Physics.
    Björkhage, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Blom, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Brännholm, Lars
    Stockholm University, Faculty of Science, Department of Physics.
    Bäckstrom, Erik
    Stockholm University, Faculty of Science, Department of Physics.
    Danared, Håkan
    Stockholm University, Faculty of Science, Department of Physics.
    Das, Susanta
    Stockholm University, Faculty of Science, Department of Physics.
    Haag, Nicole
    Stockholm University, Faculty of Science, Department of Physics.
    Halldén, Per
    Stockholm University, Faculty of Science, Department of Physics.
    Hellberg, Fredrik
    Stockholm University, Faculty of Science, Department of Physics.
    Holm, Anne I. S.
    Stockholm University, Faculty of Science, Department of Physics.
    Johansson, H. A. B.
    Stockholm University, Faculty of Science, Department of Physics.
    Källberg, Anders
    Stockholm University, Faculty of Science, Department of Physics.
    Källersjö, Gunnar
    Stockholm University, Faculty of Science, Department of Physics.
    Larsson, Mats
    Stockholm University, Faculty of Science, Department of Physics.
    Leontein, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Liljeby, Leif
    Stockholm University, Faculty of Science, Department of Physics.
    Löfgren, Patrik
    Stockholm University, Faculty of Science, Department of Physics.
    Malm, Bo
    Stockholm University, Faculty of Science, Department of Physics.
    Mannervik, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Masuda, Masaharu
    Stockholm University, Faculty of Science, Department of Physics.
    Misra, Deepankar
    Stockholm University, Faculty of Science, Department of Physics.
    Orban, A.
    Stockholm University, Faculty of Science, Department of Physics.
    Paál, Andras
    Stockholm University, Faculty of Science, Department of Physics.
    Reinhed, Peter
    Stockholm University, Faculty of Science, Department of Physics.
    Rensfelt, Karl-Gunnar
    Stockholm University, Faculty of Science, Department of Physics.
    Rosén, Stefan
    Stockholm University, Faculty of Science, Department of Physics.
    Schmidt, K.
    Stockholm University, Faculty of Science, Department of Physics.
    Seitz, Fabian
    Stockholm University, Faculty of Science, Department of Physics.
    Simonsson, Ansgar
    Stockholm University, Faculty of Science, Department of Physics.
    Weimer, Jan
    Stockholm University, Faculty of Science, Department of Physics.
    Zettergren, Henning
    Stockholm University, Faculty of Science, Department of Physics.
    Cederquist, Henrik
    Stockholm University, Faculty of Science, Department of Physics.
    The double electrostatic ion ring experiment: A unique cryogenic electrostatic storage ring for merged ion-beams studies2011In: Review of Scientific Instruments, ISSN 0034-6748, E-ISSN 1089-7623, Vol. 82, no 6, p. 065112-Article in journal (Refereed)
    Abstract [en]

    We describe the design of a novel type of storage device currently under construction at Stockholm University, Sweden, using purely electrostatic focussing and deflection elements, in which ion beams of opposite charges are confined under extreme high vacuum cryogenic conditions in separate rings and merged over a common straight section. The construction of this double electrostatic ion ring experiment uniquely allows for studies of interactions between cations and anions at low and well-defined internal temperatures and centre-of-mass collision energies down to about 10 K and 10 meV, respectively. Position sensitive multi-hit detector systems have been extensively tested and proven to work in cryogenic environments and these will be used to measure correlations between reaction products in, for example, electron-transfer processes. The technical advantages of using purely electrostatic ion storage devices over magnetic ones are many, but the most relevant are: electrostatic elements which are more compact and easier to construct; remanent fields, hysteresis, and eddy-currents, which are of concern in magnetic devices, are no longer relevant; and electrical fields required to control the orbit of the ions are not only much easier to create and control than the corresponding magnetic fields, they also set no upper mass limit on the ions that can be stored. These technical differences are a boon to new areas of fundamental experimental research, not only in atomic and molecular physics but also in the boundaries of these fields with chemistry and biology. For examples, studies of interactions with internally cold molecular ions will be particular useful for applications in astrophysics, while studies of solvated ionic clusters will be of relevance to aeronomy and biology.

  • 6.
    Thomas, Richard D.
    et al.
    Stockholm University, Faculty of Science, Department of Physics.
    Schmidt, Henning T.
    Stockholm University, Faculty of Science, Department of Physics.
    Gatchell, Michael
    Stockholm University, Faculty of Science, Department of Physics.
    Rosén, Sara
    Stockholm University, Faculty of Science, Department of Physics.
    Reinhed, Peter
    Stockholm University, Faculty of Science, Department of Physics.
    Löfgren, Patrik
    Stockholm University, Faculty of Science, Department of Physics.
    Brännholm, Lars
    Stockholm University, Faculty of Science, Department of Physics.
    Blom, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Björkhage, Mikael
    Stockholm University, Faculty of Science, Department of Physics.
    Bäckström, Erik
    Stockholm University, Faculty of Science, Department of Physics.
    Alexander, John D.
    Stockholm University, Faculty of Science, Department of Physics.
    Leontein, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Hanstorp, D.
    Zettergren, Henning
    Stockholm University, Faculty of Science, Department of Physics.
    Kaminska, Magdalena
    Stockholm University, Faculty of Science, Department of Physics.
    Nascimento, Rodrigo
    Stockholm University, Faculty of Science, Department of Physics.
    Liljeby, Leif
    Stockholm University, Faculty of Science, Department of Physics.
    Källberg, Anders
    Stockholm University, Faculty of Science, Department of Physics.
    Simonsson, Ansgar
    Stockholm University, Faculty of Science, Department of Physics.
    Hellberg, Fredrik
    Stockholm University, Faculty of Science, Department of Physics.
    Mannervik, Sven
    Stockholm University, Faculty of Science, Department of Physics.
    Larsson, Mats
    Stockholm University, Faculty of Science, Department of Physics.
    Geppert, Wolf D.
    Stockholm University, Faculty of Science, Department of Physics.
    Rensfelt, Karl-Gunnar
    Stockholm University, Faculty of Science, Department of Physics.
    Paál, Andras
    Stockholm University, Faculty of Science, Department of Physics.
    Masuda, Masaharu
    Stockholm University, Faculty of Science, Department of Physics.
    Halldén, Per
    Stockholm University, Faculty of Science, Department of Physics.
    Andler, Guillermo
    Stockholm University, Faculty of Science, Department of Physics.
    Stockett, Mark H.
    Stockholm University, Faculty of Science, Department of Physics.
    Chen, Tao
    Stockholm University, Faculty of Science, Department of Physics.
    Källersjö, Gunnar
    Stockholm University, Faculty of Science, Department of Physics.
    Weimer, Jan
    Stockholm University, Faculty of Science, Department of Physics.
    Hansen, K.
    Hartman, H.
    Cederquist, Henrik
    Stockholm University, Faculty of Science, Department of Physics.
    DESIREE: Physics with cold stored ion beams2015In: DR2013: Ninth international conference on dissociative recombination: theory, experiment, and applications, 2015, Vol. 84, article id 01004Conference paper (Refereed)
    Abstract [en]

    Here we will briefly describe the commissioning of the Double ElectroStatic Ion Ring ExpEriment (DESIREE) facility at Stockholm University, Sweden. This device uses purely electrostatic focussing and deflection elements and allows ion beams of opposite charge to be confined under extreme high vacuum and cryogenic conditions in separate rings and then merged over a common straight section. This apparatus allows for studies of interactions between cations and anions at very low and well-defined centre-of-mass energies (down to a few meV) and at very low internal temperatures (down to a few K).

1 - 6 of 6
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf