Endre søk
Link to record
Permanent link

Direct link
Joy, Ashley
Publikasjoner (10 av 15) Visa alla publikasjoner
Antochi, V. C., Conrad, J., Rosso, A. G., Joy, A., Mahlstedt, J. & Tan, P.-L. (2024). Design and performance of the field cage for the XENONnT experiment. European Physical Journal C, 84(2), Article ID 138.
Åpne denne publikasjonen i ny fane eller vindu >>Design and performance of the field cage for the XENONnT experiment
Vise andre…
2024 (engelsk)Inngår i: European Physical Journal C, ISSN 1434-6044, E-ISSN 1434-6052, Vol. 84, nr 2, artikkel-id 138Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field shaping rings connected by an easily accessible resistor chain. Rather than being connected to the gate electrode, the topmost field shaping ring is independently biased, adding a degree of freedom to tune the electric field during operation. Two-dimensional finite element simulations were used to optimize the field cage, as well as its operation. Simulation results were compared to 83mKr calibration data. This comparison indicates an accumulation of charge on the panels of the TPC which is constant over time, as no evolution of the reconstructed position distribution of events is observed. The simulated electric field was then used to correct the charge signal for the field dependence of the charge yield. This correction resolves the inconsistent measurement of the drift electron lifetime when using different calibrations sources and different field cage tuning voltages.

HSV kategori
Identifikatorer
urn:nbn:se:su:diva-226992 (URN)10.1140/epjc/s10052-023-12296-y (DOI)001159991600006 ()2-s2.0-85195205079 (Scopus ID)
Tilgjengelig fra: 2024-03-04 Laget: 2024-03-04 Sist oppdatert: 2025-02-14bibliografisk kontrollert
Aprile, E., Antochi, V. C., Conrad, J., Rosso, A. G., Joy, A., Mahlstedt, J., . . . Zhu, T. (2024). Effective field theory and inelastic dark matter results from XENON1T. Physical Review D: covering particles, fields, gravitation, and cosmology, 109(11), Article ID 112017.
Åpne denne publikasjonen i ny fane eller vindu >>Effective field theory and inelastic dark matter results from XENON1T
Vise andre…
2024 (engelsk)Inngår i: Physical Review D: covering particles, fields, gravitation, and cosmology, ISSN 2470-0010, E-ISSN 2470-0029, Vol. 109, nr 11, artikkel-id 112017Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In this work, we expand on the XENON1T nuclear recoil searches to study the individual signals of dark matter interactions from operators up to dimension eight in a chiral effective field theory (ChEFT) and a model of inelastic dark matter (iDM). We analyze data from two science runs of the XENON1T detector totaling 1  t × yr exposure. For these analyses, we extended the region of interest from [4.9, 40.9]  keVNR to [4.9, 54.4]  keVNR to enhance our sensitivity for signals that peak at nonzero energies. We show that the data are consistent with the background-only hypothesis, with a small background overfluctuation observed peaking between 20 and 50  keVNR, resulting in a maximum local discovery significance of 1.7⁢𝜎 for the Vector ⊗ Vectorstrange ChEFT channel for a dark matter particle of 70  GeV/𝑐2 and 1.8⁢𝜎 for an iDM particle of 50  GeV/𝑐2 with a mass splitting of 100  keV/𝑐2. For each model, we report 90% confidence level upper limits. We also report upper limits on three benchmark models of dark matter interaction using ChEFT where we investigate the effect of isospin-breaking interactions. We observe rate-driven cancellations in regions of the isospin-breaking couplings, leading to up to 6 orders of magnitude weaker upper limits with respect to the isospin-conserving case.

Emneord
Dark Matter, Chiral Effective Field Theory, Inelastic Dark Matter
HSV kategori
Forskningsprogram
fysik
Identifikatorer
urn:nbn:se:su:diva-203646 (URN)10.1103/PhysRevD.109.112017 (DOI)001351430400001 ()2-s2.0-85196734763 (Scopus ID)
Tilgjengelig fra: 2022-04-11 Laget: 2022-04-11 Sist oppdatert: 2025-10-02bibliografisk kontrollert
Aprile, E., Conrad, J., Flehmke, T., Joy, A., Mahlstedt, J., Tan, P.-L. & Zhu, T. (2024). Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon time projection chambers. Physical Review D: covering particles, fields, gravitation, and cosmology, 110(1), Article ID 012011.
Åpne denne publikasjonen i ny fane eller vindu >>Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon time projection chambers
Vise andre…
2024 (engelsk)Inngår i: Physical Review D: covering particles, fields, gravitation, and cosmology, ISSN 2470-0010, E-ISSN 2470-0029, Vol. 110, nr 1, artikkel-id 012011Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using Rn222 and Po218 events, and the rms convection speed was measured to be 0.30±0.01 cm/s. Given this velocity field, Pb214 background events can be tagged when they are followed by Bi214 and Po214 decays, or preceded by Po218 decays. This was achieved by evolving a point cloud in the direction of a measured convection velocity field, and searching for Bi214 and Po214 decays or Po218 decays within a volume defined by the point cloud. In XENON1T, this tagging system achieved a Pb214 background reduction of 6.2-0.9+0.4% with an exposure loss of 1.8±0.2%, despite the timescales of convection being smaller than the relevant decay times. We show that the performance can be improved in XENONnT, and that the performance of such a software-tagging approach can be expected to be further improved in a diffusion-limited scenario. Finally, a similar method might be useful to tag the cosmogenic Xe137 background, which is relevant to the search for neutrinoless double-beta decay.

HSV kategori
Identifikatorer
urn:nbn:se:su:diva-238549 (URN)10.1103/PhysRevD.110.012011 (DOI)001437445200001 ()2-s2.0-85199001683 (Scopus ID)
Tilgjengelig fra: 2025-01-28 Laget: 2025-01-28 Sist oppdatert: 2025-10-02bibliografisk kontrollert
Aprile, E., Antochi, V. C., Conrad, J., Rosso, A. G., Joy, A., Mahlstedt, J., . . . Zhu, T. (2024). The XENONnT dark matter experiment. European Physical Journal C, 84(8), Article ID 784.
Åpne denne publikasjonen i ny fane eller vindu >>The XENONnT dark matter experiment
Vise andre…
2024 (engelsk)Inngår i: European Physical Journal C, ISSN 1434-6044, E-ISSN 1434-6052, Vol. 84, nr 8, artikkel-id 784Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.

HSV kategori
Identifikatorer
urn:nbn:se:su:diva-238110 (URN)10.1140/epjc/s10052-024-12982-5 (DOI)001286427500002 ()2-s2.0-85200962024 (Scopus ID)
Tilgjengelig fra: 2025-01-20 Laget: 2025-01-20 Sist oppdatert: 2025-01-20bibliografisk kontrollert
Antochi, V. C., Blanco, C., Conrad, J., Emken, T., Joy, A., Mahlstedt, J., . . . Tan, P.-L. (2023). A next-generation liquid xenon observatory for dark matter and neutrino physics. Journal of Physics G: Nuclear and Particle Physics, 50(1), Article ID 013001.
Åpne denne publikasjonen i ny fane eller vindu >>A next-generation liquid xenon observatory for dark matter and neutrino physics
Vise andre…
2023 (engelsk)Inngår i: Journal of Physics G: Nuclear and Particle Physics, ISSN 0954-3899, E-ISSN 1361-6471, Vol. 50, nr 1, artikkel-id 013001Artikkel, forskningsoversikt (Fagfellevurdert) Published
Abstract [en]

The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for weakly interacting massive particles, while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.

Emneord
dark matter, neutrinoless double-beta decay, neutrinos, supernova, direct detection, astroparticle physics, xenon
HSV kategori
Identifikatorer
urn:nbn:se:su:diva-215894 (URN)10.1088/1361-6471/ac841a (DOI)000928191300001 ()2-s2.0-85145605367 (Scopus ID)
Tilgjengelig fra: 2023-03-29 Laget: 2023-03-29 Sist oppdatert: 2023-03-29bibliografisk kontrollert
Aprile, E., Antochi, V. C., Conrad, J., Rosso, A. G., Joy, A., Mahlstedt, J., . . . Zhu, T. (2023). Detector signal characterization with a Bayesian network in XENONnT. Physical Review D: covering particles, fields, gravitation, and cosmology, 108(1), Article ID 012016.
Åpne denne publikasjonen i ny fane eller vindu >>Detector signal characterization with a Bayesian network in XENONnT
Vise andre…
2023 (engelsk)Inngår i: Physical Review D: covering particles, fields, gravitation, and cosmology, ISSN 2470-0010, E-ISSN 2470-0029, Vol. 108, nr 1, artikkel-id 012016Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

We developed a detector signal characterization model based on a Bayesian network trained on the waveform attributes generated by a dual-phase xenon time projection chamber. By performing inference on the model, we produced a quantitative metric of signal characterization and demonstrate that this metric can be used to determine whether a detector signal is sourced from a scintillation or an ionization process. We describe the method and its performance on electronic-recoil (ER) data taken during the first science run of the XENONnT dark matter experiment. We demonstrate the first use of a Bayesian network in a waveform -based analysis of detector signals. This method resulted in a 3% increase in ER event-selection efficiency with a simultaneously effective rejection of events outside of the region of interest. The findings of this analysis are consistent with the previous analysis from XENONnT, namely a background-only fit of the ER data.

HSV kategori
Identifikatorer
urn:nbn:se:su:diva-223219 (URN)10.1103/PhysRevD.108.012016 (DOI)001056646500002 ()2-s2.0-85166773655 (Scopus ID)
Tilgjengelig fra: 2023-12-06 Laget: 2023-12-06 Sist oppdatert: 2023-12-07bibliografisk kontrollert
Aprile, E., Antochi, V. C., Conrad, J., Rosso, A. G., Joy, A., Mahlstedt, J., . . . Zhu, T. (2023). First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment. Physical Review Letters, 131(4), Article ID 041003.
Åpne denne publikasjonen i ny fane eller vindu >>First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
Vise andre…
2023 (engelsk)Inngår i: Physical Review Letters, ISSN 0031-9007, E-ISSN 1079-7114, Vol. 131, nr 4, artikkel-id 041003Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment, which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of 5.9 ton. During the (1.09±0.03)  ton yr exposure used for this search, the intrinsic 85Kr and 222Rn concentrations in the liquid target are reduced to unprecedentedly low levels, giving an electronic recoil background rate of (15.8±1.3)  events/ton yr keV in the region of interest. A blind analysis of nuclear recoil events with energies between 3.3 and 60.5 keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of 2.58×10−47  cm2 for a WIMP mass of 28  GeV/c2 at 90% confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.

HSV kategori
Identifikatorer
urn:nbn:se:su:diva-223217 (URN)10.1103/PhysRevLett.131.041003 (DOI)001062122500003 ()37566859 (PubMedID)2-s2.0-85166740574 (Scopus ID)
Tilgjengelig fra: 2023-12-01 Laget: 2023-12-01 Sist oppdatert: 2023-12-07bibliografisk kontrollert
Antochi, V. C., Conrad, J., Gallo Rosso, A., Joy, A., Mahlstedt, J. & Tan, P.-L. (2023). Low-energy calibration of XENON1T with an internal 37Ar source. European Physical Journal C, 83(6), Article ID 542.
Åpne denne publikasjonen i ny fane eller vindu >>Low-energy calibration of XENON1T with an internal 37Ar source
Vise andre…
2023 (engelsk)Inngår i: European Physical Journal C, ISSN 1434-6044, E-ISSN 1434-6052, Vol. 83, nr 6, artikkel-id 542Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal 37Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3±0.3) photons/keV and (40.6±0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0+6.3−3.7) electrons/keV. The 37Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83±0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that 37Ar can be considered as a regular calibration source for multi-tonne xenon detectors.

HSV kategori
Identifikatorer
urn:nbn:se:su:diva-225073 (URN)10.1140/epjc/s10052-023-11512-z (DOI)001068182400004 ()2-s2.0-85163608131 (Scopus ID)
Tilgjengelig fra: 2024-01-09 Laget: 2024-01-09 Sist oppdatert: 2024-01-09bibliografisk kontrollert
Aprile, E., Antochi, V. C., Conrad, J., Rosso, A. G., Joy, A., Mahlstedt, J., . . . Zhu, T. (2023). Search for events in XENON1T associated with gravitational waves. Physical Review D: covering particles, fields, gravitation, and cosmology, 108(7), Article ID 072015.
Åpne denne publikasjonen i ny fane eller vindu >>Search for events in XENON1T associated with gravitational waves
Vise andre…
2023 (engelsk)Inngår i: Physical Review D: covering particles, fields, gravitation, and cosmology, ISSN 2470-0010, E-ISSN 2470-0029, Vol. 108, nr 7, artikkel-id 072015Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

We perform a blind search for particle signals in the XENON1T dark matter detector that occur close in time to gravitational-wave signals in the LIGO and Virgo observatories. No particle signal is observed in the nuclear recoil and electronic recoil channels within ±500 seconds of observations of the gravitational-wave signals GW170104, GW170729, GW170817, GW170818, and GW170823. We use this null result to constrain monoenergetic neutrinos and axion-like particles emitted in the closest coalescence GW170817, a binary neutron star merger. We set new upper limits on the fluence (time-integrated flux) of coincident neutrinos down to 17 keV at the 90% confidence level. Furthermore, we constrain the product of the coincident fluence and cross section of axion-like particles to be less than 10−29  cm2/cm2 in the [5.5–210] keV energy range at the 90% confidence level.

HSV kategori
Identifikatorer
urn:nbn:se:su:diva-225370 (URN)10.1103/PhysRevD.108.072015 (DOI)001102758000001 ()2-s2.0-85178303107 (Scopus ID)
Tilgjengelig fra: 2024-01-22 Laget: 2024-01-22 Sist oppdatert: 2024-01-22bibliografisk kontrollert
Aprile, E., Conrad, J., Rosso, A. G., Joy, A., Mahlstedt, J., Tan, P.-L. & Zhu, T. (2023). Searching for Heavy Dark Matter near the Planck Mass with XENON1T. Physical Review Letters, 130(26), Article ID 261002.
Åpne denne publikasjonen i ny fane eller vindu >>Searching for Heavy Dark Matter near the Planck Mass with XENON1T
Vise andre…
2023 (engelsk)Inngår i: Physical Review Letters, ISSN 0031-9007, E-ISSN 1079-7114, Vol. 130, nr 26, artikkel-id 261002Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from multiply interacting massive particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This Letter places strong constraints on spin-independent interactions of dark matter particles with a mass between 1 x 1012 and 2 x 1017 GeV/c2. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross sections for dark matter particles with masses close to the Planck scale.

HSV kategori
Identifikatorer
urn:nbn:se:su:diva-223218 (URN)10.1103/PhysRevLett.130.261002 (DOI)001058033400011 ()37450817 (PubMedID)2-s2.0-85164537137 (Scopus ID)
Tilgjengelig fra: 2023-12-01 Laget: 2023-12-01 Sist oppdatert: 2023-12-07bibliografisk kontrollert
Organisasjoner