Change search
Link to record
Permanent link

Direct link
Publications (4 of 4) Show all publications
Arjunan, M., Sharma Shamurailatpam, D., Patro, K. C., Kaushik, S. & Krishnan, G. (2025). Influence of spatial redistribution of heterogeneities in proton beam characteristics. Physica medica (Testo stampato), 129, Article ID 104882.
Open this publication in new window or tab >>Influence of spatial redistribution of heterogeneities in proton beam characteristics
Show others...
2025 (English)In: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 129, article id 104882Article in journal (Refereed) Published
Abstract [en]

Objectives: The purpose of this study was to investigate the fundamental properties of spot-scanning proton beams and compare them to Monte Carlo (MC) simulations, both with and without CT calibration, using spatially diverse combinations of materials. Methods: A heterogeneous phantom was created by spatially distributing titanium, wax, and thermocol to generate six scenarios of heterogeneous combinations. Proton pencil beams ranging in energy from 100 to 226.2 MeV were directed perpendicular to each heterogeneous combination, and the exit proton was measured using a Lynx scintillation detector and a Zebra Multi-Layer-Ionization-Chamber for depth dose and spot profile measurements, respectively. The identical measurement configuration was duplicated in the RayStation-TPS. The measured and simulated RayStation-MC beam characteristics were compared. Results: The results showed that at 100 MeV, the mean standard deviation of spot size was 5.66 ± 0.27 mm, while at 226.2 MeV, it rapidly decreased to 3.37 ± 0.07 mm. The physical phantom showed a larger perturbation difference between measurement and MC simulation than the virtual phantom. MC overestimates ranges up to 1.5 % in virtual phantoms, but underestimates ranges up to 5 % in physical phantoms. Range perturbations over 1 mm occurred in 35.7 % of virtual phantom measurements and in 85.7 % of physical phantom measurements. Conclusions: Despite using a CT artefact reduction approach and an accurate Monte-Carlo dose calculation algorithm, perturbations in proton characteristics were still observed. It is essential to be aware of the limits of the TPS in managing such heterogeneous combinations. It is recommended to perform more validation checks on heterogeneous combinations than on individual materials.

Keywords
Dose uncertainty, Pencil beam scanning, Proton, Proton Uncertainties
National Category
Radiology and Medical Imaging
Identifiers
urn:nbn:se:su:diva-240483 (URN)10.1016/j.ejmp.2024.104882 (DOI)001397357100001 ()39752801 (PubMedID)2-s2.0-85213847609 (Scopus ID)
Available from: 2025-03-11 Created: 2025-03-11 Last updated: 2025-03-11Bibliographically approved
Kaushik, S., Vatterodt, N., Ödén, J., Fredriksson, A., Korreman, S. S. & Toma-Daşu, I. (2025). Synthetic computed tomography techniques for adaptive proton therapy in head and neck cancers. Physics and Imaging in Radiation Oncology, 36, Article ID 100847.
Open this publication in new window or tab >>Synthetic computed tomography techniques for adaptive proton therapy in head and neck cancers
Show others...
2025 (English)In: Physics and Imaging in Radiation Oncology, E-ISSN 2405-6316, Vol. 36, article id 100847Article in journal (Refereed) Published
Abstract [en]

Head and neck (HN) radiotherapy often requires corrective interventions. This study evaluated three methods for synthetic computed tomography (CT) generation for adaptive HN planning using cone-beam CT (CBCT) images. CBCT images for 15 patients were paired with same-day repeat CT scans and robustly optimized proton plans were recalculated. The anatomy-preserving virtual CT (APvCT) method utilized organs-at-risk as deformation controlling structures. APvCT and conventional virtual CT methods showed lower mean absolute errors in CT number values compared to corrected CBCT; however, all synthetic CT methods were found suitable for proton dose recalculation with gamma passing rates greater than 96.7% (2%, 2 mm).

Keywords
Synthetic CT, CBCT image correction, Adaptive proton therapy, Head and neck cancer
National Category
Cancer and Oncology Other Physics Topics
Identifiers
urn:nbn:se:su:diva-248211 (URN)10.1016/j.phro.2025.100847 (DOI)001599165100001 ()2-s2.0-105018645826 (Scopus ID)
Available from: 2025-10-17 Created: 2025-10-17 Last updated: 2026-05-05Bibliographically approved
Kaushik, S., Stützer, K., Ödén, J., Fredriksson, A. & Toma-Daşu, I. (2024). Adaptive intensity modulated proton therapy using 4D robust planning: a proof-of-concept for the application of dose mimicking approach. Physics in Medicine and Biology, 69(18), Article ID 185010.
Open this publication in new window or tab >>Adaptive intensity modulated proton therapy using 4D robust planning: a proof-of-concept for the application of dose mimicking approach
Show others...
2024 (English)In: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 69, no 18, article id 185010Article in journal (Refereed) Published
Abstract [en]

Objective. A four-dimensional robust optimisation (4DRO) is usually employed when the tumour respiratory motion needs to be addressed. However, it is computationally demanding, and an automated method is preferable for adaptive planning to avoid manual trial-and-error. This study proposes a 4DRO technique based on dose mimicking for automated adaptive planning. Approach. Initial plans for 4DRO intensity modulated proton therapy were created on an average CT for four patients with clinical target volume (CTV) in the lung, oesophagus, or pancreas, respectively. These plans were robustly optimised using three phases of four-dimensional computed tomography (4DCT) and accounting for setup and density uncertainties. Weekly 4DCTs were used for adaptive replanning, using a constant relative biological effectiveness (cRBE) of 1.1. Two methods were used: (1) template-based adaptive (TA) planning and (2) dose-mimicking-based adaptive (MA) planning. The plans were evaluated using variable RBE (vRBE) weighted doses and biologically consistent dose accumulation (BCDA). Main results. MA and TA plans had comparable CTV coverage except for one patient where the MA plan had a higher D98 and lower D2 but with an increased D2 in few organs at risk (OARs). CTV D98 deviations in non-adaptive plans from the initial plans were up to −7.2 percentage points (p.p.) in individual cases and −1.8 p.p. when using BCDA. For the OARs, MA plans showed a reduced mean dose and D2 compared to the TA plans, with few exceptions. The vRBE-weighted accumulated doses had a mean dose and D2 difference of up to 0.3 Gy and 0.5 Gy, respectively, in the OARs with respect to cRBE-weighted doses. Significance. MA plans indicate better performance in target coverage and OAR dose sparing compared to the TA plans in 4DRO adaptive planning. Moreover, MA method is capable of handling both forms of anatomical variation, namely, changes in density and relative shifts in the position of OARs.

National Category
Cancer and Oncology
Identifiers
urn:nbn:se:su:diva-235451 (URN)10.1088/1361-6560/ad75e0 (DOI)001311892500001 ()39214132 (PubMedID)2-s2.0-85204164738 (Scopus ID)
Funder
EU, Horizon 2020, 955956
Available from: 2024-11-13 Created: 2024-11-13 Last updated: 2025-05-12Bibliographically approved
Kaushik, S., Ödén, J., Sharma, D. S., Fredriksson, A. & Toma-Dasu, I. (2024). Generation and evaluation of anatomy-preserving virtual CT for online adaptive proton therapy. Medical Physics, 51(3), 1536-1546
Open this publication in new window or tab >>Generation and evaluation of anatomy-preserving virtual CT for online adaptive proton therapy
Show others...
2024 (English)In: Medical Physics, ISSN 0094-2405, E-ISSN 2473-4209, Vol. 51, no 3, p. 1536-1546Article in journal (Refereed) Published
Abstract [en]

Background: Daily CTs generated by CBCT correction are required for daily replanning in online-adaptive proton therapy (APT) to effectively deal with inter-fractional changes. Out of the currently available methods, the suitability of a daily CT generation method for proton dose calculation also depends on the anatomical site.

Purpose: We propose an anatomy-preserving virtual CT (APvCT) method as a hybrid method of CBCT correction, which is especially suitable for large anatomy deformations. The accuracy of the hybrid method was assessed by comparison with the corrected CBCT (cCBCT) and virtual CT (vCT) methods in the context of online APT.

Methods: Seventy-one daily CBCTs of four prostate cancer patients treated with intensity modulated proton therapy (IMPT) were converted to daily CTs using cCBCT, vCT, and the newly proposed APvCT method. In APvCT, planning CT (pCT) were mapped to CBCT geometry using deformable image registration with boundary conditions on controlling regions of interest (ROIs) created with deep learning segmentation on cCBCT. The relative frequency distribution (RFD) of HU, mass density and stopping power ratio (SPR) values were assessed and compared with the pCT. The ROIs in the APvCT and vCT were compared with cCBCT in terms of Dice similarity coefficient (DSC) and mean distance-to-agreement (mDTA). For each patient, a robustly optimized IMPT plan was created on the pCT and subsequent daily adaptive plans on daily CTs. For dose distribution comparison on the same anatomy, the daily adaptive plans on cCBCT and vCT were recalculated on the corresponding APvCT. The dose distributions were compared in terms of isodose volumes and 3D global gamma-index passing rate (GPR) at γ(2%, 2 mm) criterion.

Results: For all patients, no noticeable difference in RFDs was observed amongst APvCT, vCT, and pCT except in cCBCT, which showed a noticeable difference. The minimum DSC value was 0.96 and 0.39 for contours in APvCT and vCT respectively. The average value of mDTA for APvCT was 0.01 cm for clinical target volume and ≤0.01 cm for organs at risk, which increased to 0.18 cm and ≤0.52 cm for vCT. The mean GPR value was 90.9%, 64.5%, and 67.0% for APvCT versus cCBCT, vCT versus cCBCT, and APvCT versus vCT, respectively. When recalculated on APvCT, the adaptive cCBCT and vCT plans resulted in mean GPRs of 89.5 ± 5.1% and 65.9 ± 19.1%, respectively. The mean DSC values for 80.0%, 90.0%, 95.0%, 98.0%, and 100.0% isodose volumes were 0.97, 0.97, 0.97, 0.95, and 0.91 for recalculated cCBCT plans, and 0.89, 0.88, 0.87, 0.85, and 0.81 for recalculated vCT plans. Hausdorff distance for the 100.0% isodose volume in some cases of recalculated cCBCT plans on APvCT exceeded 1.00 cm.

Conclusions: APvCT contours showed good agreement with reference contours of cCBCT which indicates anatomy preservation in APvCT. A vCT with erroneous anatomy can result in an incorrect adaptive plan. Further, slightly lower values of GPR between the APvCT and cCBCT-based adaptive plans can be explained by the difference in the cCBCT's SPR RFD from the pCT.

Keywords
adaptive proton therapy, virtual/synthetic CT | daily anatomical variation
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:su:diva-226118 (URN)10.1002/mp.16941 (DOI)001143329900001 ()38230803 (PubMedID)2-s2.0-85182451194 (Scopus ID)
Available from: 2024-02-06 Created: 2024-02-06 Last updated: 2026-01-19
Organisations
Identifiers
ORCID iD: ORCID iD iconorcid.org/0000-0002-8441-3595

Search in DiVA

Show all publications