Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Low-energy calibration of XENON1T with an internal 37Ar source
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum. Stockholms universitet, Naturvetenskapliga fakulteten, Oskar Klein-centrum för kosmopartikelfysik (OKC).ORCID-id: 0000-0003-1331-2890
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum. Stockholms universitet, Naturvetenskapliga fakulteten, Oskar Klein-centrum för kosmopartikelfysik (OKC).ORCID-id: 0000-0001-9984-4411
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum. Stockholms universitet, Naturvetenskapliga fakulteten, Oskar Klein-centrum för kosmopartikelfysik (OKC).ORCID-id: 0000-0002-4664-5504
Stockholms universitet, Naturvetenskapliga fakulteten, Oskar Klein-centrum för kosmopartikelfysik (OKC). Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum.
Vise andre og tillknytning
Rekke forfattare: 1642023 (engelsk)Inngår i: European Physical Journal C, ISSN 1434-6044, E-ISSN 1434-6052, Vol. 83, nr 6, artikkel-id 542Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal 37Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3±0.3) photons/keV and (40.6±0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0+6.3−3.7) electrons/keV. The 37Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83±0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that 37Ar can be considered as a regular calibration source for multi-tonne xenon detectors.

sted, utgiver, år, opplag, sider
2023. Vol. 83, nr 6, artikkel-id 542
HSV kategori
Identifikatorer
URN: urn:nbn:se:su:diva-225073DOI: 10.1140/epjc/s10052-023-11512-zISI: 001068182400004Scopus ID: 2-s2.0-85163608131OAI: oai:DiVA.org:su-225073DiVA, id: diva2:1825155
Tilgjengelig fra: 2024-01-09 Laget: 2024-01-09 Sist oppdatert: 2024-01-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Antochi, Vasile C.Conrad, JanGallo Rosso, AndreaJoy, AshleyMahlstedt, JörnTan, Pueh-Leng

Søk i DiVA

Av forfatter/redaktør
Antochi, Vasile C.Conrad, JanGallo Rosso, AndreaJoy, AshleyMahlstedt, JörnTan, Pueh-Leng
Av organisasjonen
I samme tidsskrift
European Physical Journal C

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 57 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf