Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Precise mapping of single-stranded DNA breaks by sequence-templated erroneous DNA polymerase end-labelling
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för biokemi och biofysik. Stockholms universitet, Science for Life Laboratory (SciLifeLab).ORCID-id: 0000-0002-0680-200x
Vise andre og tillknytning
Rekke forfattare: 172025 (engelsk)Inngår i: Nature Communications, E-ISSN 2041-1723, Vol. 16, artikkel-id 7130Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The ability to analyze whether DNA contains lesions is essential in identifying mutagenic substances. Currently, the detection of single-stranded DNA breaks (SSBs) lacks precision. To address this limitation, we develop a method for sequence-templated erroneous end-labelling sequencing (STEEL-seq), which enables the mapping of SSBs. The method requires a highly error-prone DNA polymerase, so we engineer a chimeric DNA polymerase, Sloppymerase, capable of replicating DNA in the absence of one nucleotide. Following the omission of a specific nucleotide (e.g., dATP) from the reaction mixture, Sloppymerase introduces mismatches directly downstream of SSBs at positions where deoxyadenosine should occur. This mismatch pattern, coupled with the retention of sequence information flanking these sites, ensures that the identified hits are bona fide SSBs. STEEL-seq is compatible with a variety of sequencing technologies, as demonstrated using Sanger, Illumina, PacBio, and Nanopore systems. Using STEEL-seq, we determine the SSB/base pair frequency in the human genome to range between 0.7 and 3.8 × 10−6 with an enrichment in active promoter regions.

sted, utgiver, år, opplag, sider
2025. Vol. 16, artikkel-id 7130
HSV kategori
Identifikatorer
URN: urn:nbn:se:su:diva-246630DOI: 10.1038/s41467-025-62512-4ISI: 001548574700015PubMedID: 40759655Scopus ID: 2-s2.0-105012487075OAI: oai:DiVA.org:su-246630DiVA, id: diva2:1997544
Tilgjengelig fra: 2025-09-12 Laget: 2025-09-12 Sist oppdatert: 2025-09-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Martin, Marcel

Søk i DiVA

Av forfatter/redaktør
Martin, Marcel
Av organisasjonen
I samme tidsskrift
Nature Communications

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 7 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf