Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Dissociative Recombination Measurements of Chloronium Ions (D2Cl+) Using an Ion Storage Ring
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum.
Visa övriga samt affilieringar
Antal upphovsmän: 132018 (Engelska)Ingår i: Astrophysical Journal, ISSN 0004-637X, E-ISSN 1538-4357, Vol. 862, nr 2, artikel-id 166Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

We report our plasma rate coefficient and branching ratio measurements for dissociative recombination (DR) of D2Cl+ with electrons. The studies were performed in a merged-beams configuration using the TSR heavy-ion storage ring located at the Max Planck Institute for Nuclear Physics in Heidelberg, Germany. Starting with our absolute merged-beams recombination rate coefficient at a collision energy of approximate to 0 eV, we have extracted the cross section and produced a plasma rate coefficient for a translational temperature of approximate to 8 K. Furthermore, extrapolating our cross-section results using the typical low-energy DR behavior, we have generated a plasma rate coefficient for translational temperatures from 5 to 500 K. We find good agreement between our extrapolated results and previous experimental DR studies on D2Cl+. Additionally, we have investigated the three fragmentation channels for DR of D2Cl+. Here we report on the dissociation geometry of the three-body fragmentation channel, the kinetic energy released for each of the three outgoing channels, the molecular internal excitation for the two outgoing channels that produce molecular fragments, and the fragmentation branching ratios for all three channels. Our results, in combination with those of other groups, indicate that any remaining uncertainties in the DR rate coefficient for H2Cl+ appear unlikely to explain the observed discrepancies between the inferred abundances of HCl and H2Cl+ in molecular clouds and predictions from astrochemical models.

Ort, förlag, år, upplaga, sidor
2018. Vol. 862, nr 2, artikel-id 166
Nyckelord [en]
astrochemistry, ISM: clouds, ISM: molecules, methods: laboratory: molecular, molecular data, molecular processes
Nationell ämneskategori
Fysik
Identifikatorer
URN: urn:nbn:se:su:diva-158912DOI: 10.3847/1538-4357/aacefcISI: 000440726900004Scopus ID: 2-s2.0-85051495626OAI: oai:DiVA.org:su-158912DiVA, id: diva2:1240024
Tillgänglig från: 2018-08-20 Skapad: 2018-08-20 Senast uppdaterad: 2022-10-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Geppert, WolfHamberg, Mathias

Sök vidare i DiVA

Av författaren/redaktören
Geppert, WolfHamberg, Mathias
Av organisationen
Fysikum
I samma tidskrift
Astrophysical Journal
Fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 109 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf