Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Preparation of monolithic molecularly imprinted polymer sol-gel packed tips for high-throughput bioanalysis: Extraction and quantification of L-tyrosine in human plasma and urine samples utilizing liquid chromatography and tandem mass spectrometry
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för analytisk kemi.
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för analytisk kemi.
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för analytisk kemi.
Visa övriga samt affilieringar
Antal upphovsmän: 52014 (Engelska)Ingår i: Journal of chromatography. B, ISSN 1570-0232, E-ISSN 1873-376X, Vol. 967, s. 168-173Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In situ monolithic molecularly imprinted polymer sol-gel packed tips (MMSTs) were prepared and evaluated for the extraction of lung cancer biomarker L-tyrosine (Tyr) from human plasma and urine samples. Several extraction parameters such as the conditioning, washing and elution solutions, pH and time were investigated. The enrichment factor (EF) and extraction recovery (ER) were studied. MMST showed good selectivity and a high extraction recovery, and MMST as a sorbent showed good stability and repeatability. The method validation showed good regression correlation coefficients for plasma and urine samples (R-2 >= 0.996) within the concentration range of 5-1000 and 1-1000 nmol L-1 in plasma and urine samples, respectively. The lower limits of quantification (LLOQ) in the plasma and urine samples were 5 and 1 nmol L-1, respectively. The between-batch precision for Tyr in plasma ranged from 1.0 to 6.0%, and in urine it was from 1.0 to 7.0%. The results show that the developed method has more facility, stability, durability and repeatability compared with previous similar methods. To the best of our knowledge, this is the first study aimed at the selective separation of Tyr as a lung cancer biomarker by MMSTs from biological matrixes and detection by LC/MS/MS.

Ort, förlag, år, upplaga, sidor
2014. Vol. 967, s. 168-173
Nyckelord [en]
Monolithic molecularly imprinted polymer sol-gel in-tip, Tyrosine, Plasma, Urine, Liquid chromatography-tandem mass spectrometry
Nationell ämneskategori
Biologiska vetenskaper Kemi
Identifikatorer
URN: urn:nbn:se:su:diva-160588DOI: 10.1016/j.jchromb.2014.07.029ISI: 000341468600025PubMedID: 25108365Scopus ID: 2-s2.0-84907340888OAI: oai:DiVA.org:su-160588DiVA, id: diva2:1253076
Tillgänglig från: 2018-10-03 Skapad: 2018-10-03 Senast uppdaterad: 2023-12-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Moein, Mohammad MahdiEl-Beqqali, AzizaAbdel-Rehim, Mohamed

Sök vidare i DiVA

Av författaren/redaktören
Moein, Mohammad MahdiEl-Beqqali, AzizaAbdel-Rehim, Mohamed
Av organisationen
Institutionen för analytisk kemi
I samma tidskrift
Journal of chromatography. B
Biologiska vetenskaperKemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 188 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf