Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Non-targeted analysis of unexpected food contaminants using LC-HRMS
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för miljövetenskap och analytisk kemi.
Visa övriga samt affilieringar
Antal upphovsmän: 52018 (Engelska)Ingår i: Analytical and Bioanalytical Chemistry, ISSN 1618-2642, E-ISSN 1618-2650, Vol. 410, nr 22, s. 5593-5602Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A non-target analysis method for unexpected contaminants in food is described. Many current methods referred to as non-target are capable of detecting hundreds or even thousands of contaminants. However, they will typically still miss all other possible contaminants. Instead, a metabolomics approach might be used to obtain true non-target analysis. In the present work, such a method was optimized for improved detection capability at low concentrations. The method was evaluated using 19 chemically diverse model compounds spiked into milk samples to mimic unknown contamination. Other milk samples were used as reference samples. All samples were analyzed with UHPLC-TOF-MS (ultra-high-performance liquid chromatography time-of-flight mass spectrometry), using reversed-phase chromatography and electrospray ionization in positive mode. Data evaluation was performed by the software TracMass 2. No target lists of specific compounds were used to search for the contaminants. Instead, the software was used to sort out all features only occurring in the spiked sample data, i.e., the workflow resembled a metabolomics approach. Procedures for chemical identification of peaks were outside the scope of the study. Method, study design, and settings in the software were optimized to minimize manual evaluation and faulty or irrelevant hits and to maximize hit rate of the spiked compounds. A practical detection limit was established at 25 mu g/kg. At this concentration, most compounds (17 out of 19) were detected as intact precursor ions, as fragments or as adducts. Only 2 irrelevant hits, probably natural compounds, were obtained. Limitations and possible practical use of the approach are discussed.

Ort, förlag, år, upplaga, sidor
2018. Vol. 410, nr 22, s. 5593-5602
Nyckelord [en]
Non-targeted analysis, Food contaminants, Food safety, HRMS, LC-MS, Unknown analysis
Nationell ämneskategori
Biologiska vetenskaper Kemi
Identifikatorer
URN: urn:nbn:se:su:diva-160045DOI: 10.1007/s00216-018-1028-4ISI: 000441281600022PubMedID: 29594430OAI: oai:DiVA.org:su-160045DiVA, id: diva2:1255314
Tillgänglig från: 2018-10-11 Skapad: 2018-10-11 Senast uppdaterad: 2022-03-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Person

Åberg, Magnus

Sök vidare i DiVA

Av författaren/redaktören
Åberg, Magnus
Av organisationen
Institutionen för miljövetenskap och analytisk kemi
I samma tidskrift
Analytical and Bioanalytical Chemistry
Biologiska vetenskaperKemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 163 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf