Out-of-field doses from secondary radiation produced in proton therapy and the associated risk of radiation-induced cancer from a brain tumor treatment
Stockholms universitet, Naturvetenskapliga fakulteten, Fysikum.
Visa övriga samt affilieringar
Antal upphovsmän: 52018 (Engelska)Ingår i: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 53, s. 129-136Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose

To determine out-of-field doses produced in proton pencil beam scanning (PBS) therapy using Monte Carlo simulations and to estimate the associated risk of radiation-induced second cancer from a brain tumor treatment.

Methods

Simulations of out-of-field absorbed doses were performed with MCNP6 and benchmarked against measurements with tissue-equivalent proportional counters (TEPC) for three irradiation setups: two irradiations of a water phantom using proton energies of 78-147 MeV and 177-223 MeV, and one brain tumor irradiation of a whole-body phantom. Out-of-field absorbed and equivalent doses to organs in a whole-body phantom following a brain tumor treatment were subsequently simulated and used to estimate the risk of radiation-induced cancer. Additionally, the contribution of absorbed dose originating from radiation produced in the nozzle was calculated from simulations.

Results

Out-of-field absorbed doses to the TEPC ranged from 0.4 to 135 mu Gy/Gy. The average deviation between simulations and measurements of the water phantom irradiations was about 17%. The absorbed dose contribution from radiation produced in the nozzle ranged between 0 and 70% of the total dose; the contribution was however small in absolute terms. The absorbed and equivalent doses to the organs ranged between 0.2 and 60 mu Gy/Gy and 0.5-151 mu Sv/Gy. The estimated lifetime risk of radiation-induced second cancer was approximately 0.01%.

Conclusions

The agreement of out-of-field absorbed doses between measurements and simulations was good given the sources of uncertainties. Calculations of out-of-field organ doses following a brain tumor treatment indicated that proton PBS therapy of brain tumors is associated with a low risk of radiation-induced cancer.

Ort, förlag, år, upplaga, sidor
2018. Vol. 53, s. 129-136
Nyckelord [en]
Monte Carlo, Proton therapy, Out-of-field doses, Radiation-induced cancer
Nationell ämneskategori
Radiologi och bildbehandling Fysik
Forskningsämne
medicinsk strålningsfysik
Identifikatorer
URN: urn:nbn:se:su:diva-161047DOI: 10.1016/j.ejmp.2018.08.020ISI: 000445037300016PubMedID: 30241747Scopus ID: 2-s2.0-85052854366OAI: oai:DiVA.org:su-161047DiVA, id: diva2:1255875
Tillgänglig från: 2018-10-15 Skapad: 2018-10-15 Senast uppdaterad: 2022-10-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Ardenfors, OscarGudowska, Irena

Sök vidare i DiVA

Av författaren/redaktören
Ardenfors, OscarGudowska, Irena
Av organisationen
Fysikum
I samma tidskrift
Physica medica (Testo stampato)
Radiologi och bildbehandlingFysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 168 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf