Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
How to detect possible pitfalls in ePC-SAFT modelling: Extension to ionic liquids
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för material- och miljökemi (MMK). Luleå University of Technology, Sweden; Nanjing Tech University, China; Petru Poni Institute of Macromolecular Chemistry, Romania.
Visa övriga samt affilieringar
Antal upphovsmän: 52020 (Engelska)Ingår i: Fluid Phase Equilibria, ISSN 0378-3812, E-ISSN 1879-0224, Vol. 519, artikel-id 112641Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

An ion-specific electrolyte perturbed-chain statistical associating fluid theory (ePC-SAFT) has been developed to describe the thermodynamic and transport properties of ionic liquids (ILs) for developing IL-based technologies to separate CO2 from gas mixtures. However, as it has been pointed out previously, SAFT-based models can lead to a pitfall, manifesting as an additional fictitious liquid-liquid critical line connected to an additional mechanically stable critical point when modeling pure substances. In this work, a method for detecting a pitfall in ILs was developed, where an expression with ionic term for calculating the critical point with ePC-SAFT was derived and an algorithm for detecting the additional fictitious phase equilibrium for ILs was proposed. The pitfall occurrence for an extended set ILs taken from our previous work was investigated. It shows that a pitfall occurs only for one single IL among all 96 ILs in the temperature and pressure range of interest. For [C(8)mpy][BF4], at 290.27-291.78 K, a pitfall may occur at the pressures of interest; at 273.15-290.20 K, it may occur at any given pressure. The ion-specific ePC-SAFT parameters for [C(8)mpy](+) may therefore need to be modified in the future when more reliable experimental results are available for parameter fitting.

Ort, förlag, år, upplaga, sidor
2020. Vol. 519, artikel-id 112641
Nyckelord [en]
ePC-SAFT, Ionic liquids, Pitfall, Critical point, Additional phase equilibrium
Nationell ämneskategori
Maskinteknik Kemi
Identifikatorer
URN: urn:nbn:se:su:diva-183931DOI: 10.1016/j.fluid.2020.112641ISI: 000542072400004OAI: oai:DiVA.org:su-183931DiVA, id: diva2:1462079
Tillgänglig från: 2020-08-28 Skapad: 2020-08-28 Senast uppdaterad: 2022-02-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Laaksonen, Aatto

Sök vidare i DiVA

Av författaren/redaktören
Laaksonen, Aatto
Av organisationen
Institutionen för material- och miljökemi (MMK)
I samma tidskrift
Fluid Phase Equilibria
MaskinteknikKemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 35 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf