Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A Critical Review and Evaluation of Blood Microsampling Devices for Exposomics
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för miljövetenskap.ORCID-id: 0009-0003-3528-0655
Stockholms universitet, Naturvetenskapliga fakulteten, Institutionen för miljövetenskap. Stockholms universitet, Science for Life Laboratory (SciLifeLab).ORCID-id: 0000-0001-6265-4294
Antal upphovsmän: 22025 (Engelska)Ingår i: Environmental Science and Technology Letters, E-ISSN 2328-8930, Vol. 12, nr 12, s. 1595-1610Artikel, forskningsöversikt (Refereegranskat) Published
Abstract [en]

Monitoring thousands of environmental chemicals in microliter blood volumes is now possible by chemical exposomics and high-resolution mass spectrometry (HRMS). As these technologies advance toward higher throughput to support human exposome studies with millions of participants, parallel implementation of higher-frequency blood collection methods must be considered to capture the highly dynamic nature of individual exposomes. Blood microsampling devices offer a less invasive way to collect quantitative, replicate, and repeated blood samples outside the clinic, overcoming limitations of traditional venepuncture and dried blood spots. Here we critically evaluate seven popular commercial microsampling devices for their potential use in chemical exposomics by considering previous use in molecular profiling, collection volumes, compatibility with various blood fractions, and conditions for shipping, storage, and analysis. We furthermore present the first data on extractable chemical interferences leaching from six of these devices in simulated blood sampling. Nontargeted HRMS revealed greatly different chemical backgrounds between devices, with implications for method sensitivity and false-positive discovery of exogenous and endogenous molecules. The unique advantages of each microsampler should be weighed against these chemical backgrounds, and in all cases, a systematic quality control program including field and simulated collection blanks is advised for future exposome studies utilizing these emerging devices.

Ort, förlag, år, upplaga, sidor
2025. Vol. 12, nr 12, s. 1595-1610
Nyckelord [en]
analytical interferences, Blood sampling, chemical exposome, longitudinal sampling, microsample, nontargeted analysis, personal sampling
Nationell ämneskategori
Miljövetenskap
Identifikatorer
URN: urn:nbn:se:su:diva-251437DOI: 10.1021/acs.estlett.5c00707ISI: 001610016400001Scopus ID: 2-s2.0-105024751022OAI: oai:DiVA.org:su-251437DiVA, id: diva2:2031034
Tillgänglig från: 2026-01-22 Skapad: 2026-01-22 Senast uppdaterad: 2026-01-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Thiele, SolveigMartin, Jonathan W.

Sök vidare i DiVA

Av författaren/redaktören
Thiele, SolveigMartin, Jonathan W.
Av organisationen
Institutionen för miljövetenskapScience for Life Laboratory (SciLifeLab)
I samma tidskrift
Environmental Science and Technology Letters
Miljövetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 31 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf