Comparison of high-resolution mass spectrometry acquisition methods for the simultaneous quantification and identification of per- and polyfluoroalkyl substances (PFAS)
Stockholm University, Faculty of Science, Department of Materials and Environmental Chemistry (MMK). University of Melbourne, Australia.ORCID iD: 0000-0002-0089-9218
Show others and affiliations
Number of Authors: 52024 (English)In: Analytical and Bioanalytical Chemistry, ISSN 1618-2642, E-ISSN 1618-2650, Vol. 416, no 4, p. 895-912Article in journal (Refereed) Published
Abstract [en]

Simultaneous identification and quantification of per- and polyfluoroalkyl substances (PFAS) were evaluated for three quadrupole time-of-flight mass spectrometry (QTOF) acquisition methods. The acquisition methods investigated were MS-Only, all ion fragmentation (All-Ions), and automated tandem mass spectrometry (Auto-MS/MS). Target analytes were the 25 PFAS of US EPA Method 533 and the acquisition methods were evaluated by analyte response, limit of quantification (LOQ), accuracy, precision, and target-suspect screening identification limit (IL). PFAS LOQs were consistent across acquisition methods, with individual PFAS LOQs within an order of magnitude. The mean and range for MS-Only, All-Ions, and Auto-MS/MS are 1.3 (0.34–5.1), 2.1 (0.49–5.1), and 1.5 (0.20–5.1) pg on column. For fast data processing and tentative identification with lower confidence, MS-Only is recommended; however, this can lead to false-positives. Where high-confidence identification, structural characterisation, and quantification are desired, Auto-MS/MS is recommended; however, cycle time should be considered where many compounds are anticipated to be present. For comprehensive screening workflows and sample archiving, All-Ions is recommended, facilitating both quantification and retrospective analysis. This study validated HRMS acquisition approaches for quantification (based upon precursor data) and exploration of identification workflows for a range of PFAS compounds.

Place, publisher, year, edition, pages
2024. Vol. 416, no 4, p. 895-912
Keywords [en]
Analytical chemistry, Emerging contaminants, Quadrupole time-of-flight mass spectrometry (QTOF), EPA Method 533, Suspect screening
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:su:diva-225735DOI: 10.1007/s00216-023-05075-xISI: 001132498600001PubMedID: 38159142Scopus ID: 2-s2.0-85180846871OAI: oai:DiVA.org:su-225735DiVA, id: diva2:1831025
Available from: 2024-01-24 Created: 2024-01-24 Last updated: 2024-01-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Szabo, Drew

Search in DiVA

By author/editor
Szabo, Drew
By organisation
Department of Materials and Environmental Chemistry (MMK)
In the same journal
Analytical and Bioanalytical Chemistry
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 70 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf