Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Influence of spatial redistribution of heterogeneities in proton beam characteristics
Stockholm University, Faculty of Science, Department of Physics. RaySearch Laboratories AB, Sweden.ORCID iD: 0000-0002-8441-3595
Show others and affiliations
Number of Authors: 52025 (English)In: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 129, article id 104882Article in journal (Refereed) Published
Abstract [en]

Objectives: The purpose of this study was to investigate the fundamental properties of spot-scanning proton beams and compare them to Monte Carlo (MC) simulations, both with and without CT calibration, using spatially diverse combinations of materials. Methods: A heterogeneous phantom was created by spatially distributing titanium, wax, and thermocol to generate six scenarios of heterogeneous combinations. Proton pencil beams ranging in energy from 100 to 226.2 MeV were directed perpendicular to each heterogeneous combination, and the exit proton was measured using a Lynx scintillation detector and a Zebra Multi-Layer-Ionization-Chamber for depth dose and spot profile measurements, respectively. The identical measurement configuration was duplicated in the RayStation-TPS. The measured and simulated RayStation-MC beam characteristics were compared. Results: The results showed that at 100 MeV, the mean standard deviation of spot size was 5.66 ± 0.27 mm, while at 226.2 MeV, it rapidly decreased to 3.37 ± 0.07 mm. The physical phantom showed a larger perturbation difference between measurement and MC simulation than the virtual phantom. MC overestimates ranges up to 1.5 % in virtual phantoms, but underestimates ranges up to 5 % in physical phantoms. Range perturbations over 1 mm occurred in 35.7 % of virtual phantom measurements and in 85.7 % of physical phantom measurements. Conclusions: Despite using a CT artefact reduction approach and an accurate Monte-Carlo dose calculation algorithm, perturbations in proton characteristics were still observed. It is essential to be aware of the limits of the TPS in managing such heterogeneous combinations. It is recommended to perform more validation checks on heterogeneous combinations than on individual materials.

Place, publisher, year, edition, pages
2025. Vol. 129, article id 104882
Keywords [en]
Dose uncertainty, Pencil beam scanning, Proton, Proton Uncertainties
National Category
Radiology and Medical Imaging
Identifiers
URN: urn:nbn:se:su:diva-240483DOI: 10.1016/j.ejmp.2024.104882ISI: 001397357100001PubMedID: 39752801Scopus ID: 2-s2.0-85213847609OAI: oai:DiVA.org:su-240483DiVA, id: diva2:1943793
Available from: 2025-03-11 Created: 2025-03-11 Last updated: 2025-03-11Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Kaushik, Suryakant

Search in DiVA

By author/editor
Kaushik, Suryakant
By organisation
Department of Physics
In the same journal
Physica medica (Testo stampato)
Radiology and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 73 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf