Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Continuous Serial Electron Diffraction for High Quality Protein Structures
Stockholm University, Faculty of Science, Department of Chemistry. (Xiaodong Zou)ORCID iD: 0000-0002-9248-6989
Stockholm University, Faculty of Science, Department of Chemistry. (Xiaodong Zou)ORCID iD: 0000-0002-7398-1124
Stockholm University, Faculty of Science, Department of Chemistry. (Xiaodong Zou)ORCID iD: 0009-0005-6090-8736
Stockholm University, Faculty of Science, Department of Chemistry. (Xiaodong Zou)ORCID iD: 0009-0008-1551-2515
Show others and affiliations
(English)Manuscript (preprint) (Other academic)
Abstract [en]

Determining macromolecular structures is crucial for understanding biological mechanisms and advancing drug discovery. Recent advancements have highlighted the potential of electron diffraction using continuous sample rotation (MicroED) for resolving these structures from sub-micrometre-sized crystals. However, the achievable data quality of MicroED on proteins is limited by radiation damage of the crystal during collection. Serial electron diffraction (SerialED) avoids this issue by merging single-shot diffraction patterns from thousands of crystals. Despite its potential, the widespread use of SerialED has been limited by the complexity and rarity of the required equipment to acquire these single shot data. Here, we show a new continuous SerialED protocol that is simple, robust and universally accessible. It quickly and efficiently collects all diffraction data from an area without the need for prior crystal identification and enables structure determination of proteins at atomic resolution (0.83 Å) on widely available hardware. Furthermore, we found this technique to produce virtually radiation damage free structures, allowing us to measure radiation sensitive local chemical details and investigate protein-ligand interactions to state-of-the-art accuracy. Continuous SerialED significantly enhances the applicability of ED in structural biology by providing convenient, fast, and high-resolution data collection with minimal radiation damage. These advancements position continuous SerialED as a transformative tool in structural biology by providing high-quality protein structures using tools already available to scientists. We anticipate our protocol to enable a wide range of studies that require high quality diffraction data of radiation sensitive materials.

National Category
Structural Biology
Research subject
Physical Chemistry; Structural Biology
Identifiers
URN: urn:nbn:se:su:diva-241602OAI: oai:DiVA.org:su-241602DiVA, id: diva2:1949189
Funder
EU, Horizon 2020, 956099Swedish Research Council, 2019-00815Swedish Research Council, 2022-03596Knut and Alice Wallenberg Foundation, 2019.0124Science for Life Laboratory, SciLifeLabAvailable from: 2025-04-01 Created: 2025-04-01 Last updated: 2025-09-03
In thesis
1. Developing Electron Diffraction Methods to Probe Oxidation States in Metalloenzymes
Open this publication in new window or tab >>Developing Electron Diffraction Methods to Probe Oxidation States in Metalloenzymes
2025 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Many proteins rely on metal ions for function, with their oxidation states (OS) playing a crucial role in enzymatic reactions. Determining OS alongside structural information enables more detailed studies of metalloenzyme reaction mechanisms. Electron crystallography techniques, specifically three-dimensional electron diffraction (3D ED/MicroED) and serial electron diffraction (SerialED), offer a unique approach for OS determination with structural detail, as electrons are particularly sensitive to charge distributions by probing the electrostatic potential. However, accurately inferring OS from electrostatic potential maps remains challenging due to limitations in data collection and processing protocols, as well as constraints in available atomic scattering models used for refinement. This thesis investigates the challenges and feasibility of OS determination from iron complexes and iron-containing enzymes using electron diffraction data.

To improve the resolution and accuracy of the electrostatic potential maps, 3D ED data acquisition and processing protocols were optimised for microcrystals of two proteins. Increasing data redundancy and using smaller overlapping wedges with high electron flux significantly improved signal-to-noise ratio, completeness, and resolution if the data.

To study the impact of different atomic scattering models, both independent atom model (IAM) and transferable aspherical atom model (TAAM) were evaluated for refinement of an iron complex against 3D ED data. The results demonstrated that IAM significantly overestimates the impact of different OS on the atomic scattering amplitude. In contrast, TAAM significantly improved refinement accuracy and reduced map noise, highlighting the importance of accurate atomic scattering models for interpreting the electrostatic potential map.

A new SerialED protocol improved the resolution of the diffraction data of an iron-containing protein from 2.4 Å to 1.3 Å. More importantly, it minimized site-specific radiation damage at the iron site. This protocol was then used for experimental and theoretical analyses of another iron-containing protein in two different redox states. Isomorphous difference maps between the two redox states revealed a signal residing at the iron positions. Model-derived structure factors using TAAM indicated that changes in iron OS significantly contribute to the isomorphous difference map and cause up to a 50% change in specific reflection intensities. These findings suggest that differences in structure factor amplitudes due to OS changes are already detectable within the current precision of the data.

This thesis lays the foundation for using electron crystallography to investigate metal-ion OS in metalloenzymes by optimising 3D ED data acquisition, developing a SerialED protocol that generates high-resolution data while minimizing radiation damage, assessing different methods for modelling metals of various OS, and evaluating the theoretical impact of changes in OS on electrostatic potential maps in a model protein. These advancements enhance electrostatic potential map accuracy and OS determination, paving the way for future mechanistic studies of redox reactions in metalloenzymes.

Place, publisher, year, edition, pages
Stockholm: Department of Chemistry, Stockholm University, 2025. p. 147
Keywords
three-dimensional electron diffraction, microcrystal electron diffraction, serial electron diffraction, oxidation states, proteins, metalloenzymes, independent atom model, transferable aspheric atom model, crystallography
National Category
Physical Chemistry Structural Biology
Research subject
Physical Chemistry
Identifiers
urn:nbn:se:su:diva-241600 (URN)978-91-8107-208-2 (ISBN)978-91-8107-209-9 (ISBN)
Public defence
2025-05-23, Magnélisalen, Kemiska övningslaboratoriet, Svante Arrhenius väg 16B, Stockholm, 09:00 (English)
Opponent
Supervisors
Funder
Swedish Research Council, 2019-00815Swedish Research Council, 2021-03992Knut and Alice Wallenberg Foundation, 2018.0237Knut and Alice Wallenberg Foundation, 2023.0201
Available from: 2025-04-25 Created: 2025-04-03 Last updated: 2025-04-16Bibliographically approved
2. Structure Determination of Proteins and Protein-ligand Complexes Using Electron Diffraction
Open this publication in new window or tab >>Structure Determination of Proteins and Protein-ligand Complexes Using Electron Diffraction
2025 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Macromolecular crystallography provides high-resolution structural information of proteins and protein-ligand complexes, offering essential insights for structure-based drug discovery. Electron diffraction methods, including three-dimensional electron diffraction (3D ED), also known as micro-crystal electron diffraction (MicroED), and serial electron diffraction (SerialED), enable structure determination from nanocrystals and are particularly useful for macromolecules that cannot form large crystals or require long crystallization times. However, the application of electron diffraction to macromolecular structure determination remains challenging, owing to limitations in sample preparation, beam-induced damage, and the efficiency of data processing. To overcome these difficulties, multiple methods and workflows were developed and systematically optimized in this thesis. 

For sample preparation, a rapid mixing protein crystallization (RaMiC) method combined with a surfactant-assisted grid preparation strategy was established. Through this method, cryogenic electron microscopy (cryo-EM) grids containing well-ordered sub-micron-sized crystals suitable for electron diffraction can be reproducibly prepared. To simplify and streamline MicroED data processing, a graphical platform named Automated Real-time and Offline Batch MicroED Data Processing Graphical User Interface (AutoLEI) was developed. It enables high-throughput offline batch processing of large numbers of datasets within minutes and supports online real-time processing. To further reduce electron beam damage, a continuous SerialED (c-SerialED) method was developed, and as a benchmark, the triclinic lysozyme structure was determined at 0.83 Å resolution. From the generated difference map, potential positions for hydrogen atoms were directly identified. 

Based on these developments, a structure-based drug discovery workflow integrating RaMiC, rapid soaking, real-time MicroED ligand screening and high-resolution c-SerialED structure determination was established. To validate the workflow, crystals of the human protein MutT homolog 1 (MTH1) were soaked individually with four ligands, and the method was applied to determine whether they bind to the protein’s active site. With soaking times as short as 3 seconds, binding could be preliminarily evaluated by real-time MicroED within 25-50 minutes. For three ligands that passed pre-screening, c-SerialED data were collected and structures of protein-ligand complexes were solved at 1.7 Å resolution. The electrostatic potential maps clearly revealed the binding modes. 

In summary, this thesis establishes a practical workflow for high-resolution protein and protein-ligand complex structure determination by electron diffraction, highlighting its potential in structure-based drug discovery.

Place, publisher, year, edition, pages
Stockholm: Department of Chemistry, Stockholm University, 2025. p. 92
Keywords
three-dimensional electron diffraction, microcrystal electron diffraction, continuous serial electron diffraction, rapid mixing protein crystallization, real-time data processing, proteins, protein-ligand interaction, crystallography
National Category
Physical Chemistry Structural Biology
Research subject
Physical Chemistry
Identifiers
urn:nbn:se:su:diva-246505 (URN)978-91-8107-378-2 (ISBN)978-91-8107-379-9 (ISBN)
Public defence
2025-10-17, Magnélisalen, Kemiska övningslaboratoriet, Svante Arrhenius väg 16B, Stockholm, 09:00 (English)
Opponent
Supervisors
Funder
EU, Horizon 2020, 956099Swedish Research Council, 2019-00815Swedish Research Council, 2022-03681Swedish Research Council, 2022-03596Knut and Alice Wallenberg Foundation, 2019.0124Science for Life Laboratory, SciLifeLab
Available from: 2025-09-24 Created: 2025-09-03 Last updated: 2025-09-19Bibliographically approved

Open Access in DiVA

No full text in DiVA

Search in DiVA

By author/editor
Hofer, GerhardWang, LeiPacoste, LauraHager, PaulFonjallaz, AlexisWilliams, LewisScaletti Hutchinson, EmmaDi Palma, MicheleStenmark, PålJonathan, WorralSteiner, Roberto A.Xu, HongyiZou, Xiaodong
By organisation
Department of ChemistryDepartment of Biochemistry and Biophysics
Structural Biology

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 1191 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf